Visual functions after photocoagulation in central serous chorioretinopathy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F10%3A10077873" target="_blank" >RIV/00216208:11150/10:10077873 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Visual functions after photocoagulation in central serous chorioretinopathy
Popis výsledku v původním jazyce
The authors evalute the visual functions of patients with unilateral central serous chorioretinopathy (CSC) and compare them with their non-affected eye and with a control group. Fourteen patients with CSC treated with direct laser-photocoagulation wereexamined preoperatively and followed-up, up to 2 years postoperatively. Baseline best corrected visual acuity (BCVA) and contrast sensitivity (CS) of both eyes of patients was significantly lower in comparison with the controls. The final BCVA and CS ofpatients did not differ significantly from the controls, except CS of affected eyes in the spatial frequency of 3.69 c/deg. Two years after laser treatment, there were only nonsignificant differences of both photopic full-field electroretinography (phERG) and multifocal electroretinography (mfERG) responses between the treated, the nonaffected eye of the patients and the control group. Functional examination methods do not prove complete resolution of function 2 years after laser-treatme
Název v anglickém jazyce
Visual functions after photocoagulation in central serous chorioretinopathy
Popis výsledku anglicky
The authors evalute the visual functions of patients with unilateral central serous chorioretinopathy (CSC) and compare them with their non-affected eye and with a control group. Fourteen patients with CSC treated with direct laser-photocoagulation wereexamined preoperatively and followed-up, up to 2 years postoperatively. Baseline best corrected visual acuity (BCVA) and contrast sensitivity (CS) of both eyes of patients was significantly lower in comparison with the controls. The final BCVA and CS ofpatients did not differ significantly from the controls, except CS of affected eyes in the spatial frequency of 3.69 c/deg. Two years after laser treatment, there were only nonsignificant differences of both photopic full-field electroretinography (phERG) and multifocal electroretinography (mfERG) responses between the treated, the nonaffected eye of the patients and the control group. Functional examination methods do not prove complete resolution of function 2 years after laser-treatme
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FF - ORL, oftalmologie, stomatologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Medica (Hradec Kralove) / Universitas Carolina, Facultas Medica Hradec Kralove
ISSN
1211-4286
e-ISSN
—
Svazek periodika
53
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—