In situ assessment of the renal microcirculation in mechanically ventilated rats using sidestream dark-field imaging
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F15%3A10284231" target="_blank" >RIV/00216208:11150/15:10284231 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00179906:_____/15:10284231 RIV/00843989:_____/15:E0104823
Výsledek na webu
<a href="http://onlinelibrary.wiley.com.ezproxy.is.cuni.cz/doi/10.1111/jmi.12198/epdf" target="_blank" >http://onlinelibrary.wiley.com.ezproxy.is.cuni.cz/doi/10.1111/jmi.12198/epdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/jmi.12198" target="_blank" >10.1111/jmi.12198</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In situ assessment of the renal microcirculation in mechanically ventilated rats using sidestream dark-field imaging
Popis výsledku v původním jazyce
For microcirculation research there is a need for baseline data and feasibility protocols describing microcirculation of various organs. The aim of our study was to examine the reliability and reproducibility of sidestream dark-field (SDF) imaging withinthe renal cortical microcirculation in rats. Renal microcirculation was observed using SDF probe placed on the exposed renal surface via the upper midline laparotomy. Video sequences recorded intermittently in short apneic pauses were analyzed off-lineby using AVA 3.0 software (MicroVision Medical, Amsterdam, the Netherlands). Results are expressed as mean (SD) or median (25-75% percentiles). We obtained 60 clear sequences from all recorded analyzable videos from all the animals. The total small vessel and all vessel density (in mm.mm(-2) ) were (28.79 +- 0.40) and (28.95 +- 0.40), respectively. The perfused small and all vessel density were (28.79 +- 0.40) and (28.95 +- 0.40), respectively. The DeBacker Score was (19.14 +- 0.43), the
Název v anglickém jazyce
In situ assessment of the renal microcirculation in mechanically ventilated rats using sidestream dark-field imaging
Popis výsledku anglicky
For microcirculation research there is a need for baseline data and feasibility protocols describing microcirculation of various organs. The aim of our study was to examine the reliability and reproducibility of sidestream dark-field (SDF) imaging withinthe renal cortical microcirculation in rats. Renal microcirculation was observed using SDF probe placed on the exposed renal surface via the upper midline laparotomy. Video sequences recorded intermittently in short apneic pauses were analyzed off-lineby using AVA 3.0 software (MicroVision Medical, Amsterdam, the Netherlands). Results are expressed as mean (SD) or median (25-75% percentiles). We obtained 60 clear sequences from all recorded analyzable videos from all the animals. The total small vessel and all vessel density (in mm.mm(-2) ) were (28.79 +- 0.40) and (28.95 +- 0.40), respectively. The perfused small and all vessel density were (28.79 +- 0.40) and (28.95 +- 0.40), respectively. The DeBacker Score was (19.14 +- 0.43), the
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Microscopy
ISSN
0022-2720
e-ISSN
—
Svazek periodika
257
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
161-165
Kód UT WoS článku
000347382100009
EID výsledku v databázi Scopus
2-s2.0-84920272543