Noninvasive assessment of the iridial microcirculation in rats using sidestream dark field imaging
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F13%3A10134318" target="_blank" >RIV/00179906:_____/13:10134318 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/13:10134318
Výsledek na webu
<a href="http://dx.doi.org/10.1111/jmi.12000" target="_blank" >http://dx.doi.org/10.1111/jmi.12000</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/jmi.12000" target="_blank" >10.1111/jmi.12000</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Noninvasive assessment of the iridial microcirculation in rats using sidestream dark field imaging
Popis výsledku v původním jazyce
Sidestream dark field imaging represents a novel, noninvasive method to study the microcirculation in humans and animals.To-date, it has been used extensively in various peripheral tissues (e.g. sublingual area, intestinal mucosa), however no data for the ocular vasculature, including the iridial microcirculation, are currently available. Therefore, the aim of this study was to examine the reliability and reproducibility of sidestream dark field imaging within the iridial microcirculation in experimental animals. Male Lewis rats were anaesthetized and the iris microvasculature was observed using an sidestream dark field probe gently placed against a cover slip covering the right eye. All video sequences recorded were analysed off-line by using AVA 3.0software (MicroVision Medical).Results are expressed as mean (+/-SE) or median (interquartile range). Clear images were recorded from each animal and the total number of analysable video sequences was 50. All raw data for selected vessel
Název v anglickém jazyce
Noninvasive assessment of the iridial microcirculation in rats using sidestream dark field imaging
Popis výsledku anglicky
Sidestream dark field imaging represents a novel, noninvasive method to study the microcirculation in humans and animals.To-date, it has been used extensively in various peripheral tissues (e.g. sublingual area, intestinal mucosa), however no data for the ocular vasculature, including the iridial microcirculation, are currently available. Therefore, the aim of this study was to examine the reliability and reproducibility of sidestream dark field imaging within the iridial microcirculation in experimental animals. Male Lewis rats were anaesthetized and the iris microvasculature was observed using an sidestream dark field probe gently placed against a cover slip covering the right eye. All video sequences recorded were analysed off-line by using AVA 3.0software (MicroVision Medical).Results are expressed as mean (+/-SE) or median (interquartile range). Clear images were recorded from each animal and the total number of analysable video sequences was 50. All raw data for selected vessel
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Microscopy
ISSN
0022-2720
e-ISSN
—
Svazek periodika
249
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
119-123
Kód UT WoS článku
000313984400006
EID výsledku v databázi Scopus
—