Comparison between optical and digital blur using near visual acuity
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F21%3A10423169" target="_blank" >RIV/00216208:11150/21:10423169 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=JmI6TMBgTQ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=JmI6TMBgTQ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-021-82965-z" target="_blank" >10.1038/s41598-021-82965-z</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison between optical and digital blur using near visual acuity
Popis výsledku v původním jazyce
In a low-cost laboratory setup, we compared visual acuity (VA) for stimuli rendered with Zernike aberrations to an equivalent optical dioptric defocus in emmetropic individuals using a relatively short observing distance of 60 cm. The equivalent spherical refractive error of+ 1, + 2 or + 4 D, was applied in the rendering of Landolt Rings. Separately, the refractive error was introduced dioptrically in: (1) unchanged Landolt Rings with an added external lens (+1, + 2 or + 4 D) at the subject's eye; (2) same as (1) but with an added accommodation and a vertex distance adjustment. To compare all three approaches, we examined VA in 10 healthy men. Stimuli were observed on a PC CRT screen. For all three levels of refractive error, the pairwise comparison did not show a statistically signifcant diference between digital blur and accommodation-plus-vertex-distance-adjusted dioptric blur (p< 0.204). The best agreement, determined by Bland-Altman analysis, was measured for+ 4 D and was in line with test-retest limits for examination in the clinical population. Our results show that even for a near observing distance, it is possible to use digitally rendered defocus to replicate dioptric blur without a signifcant change in VA in emmetropic subjects.
Název v anglickém jazyce
Comparison between optical and digital blur using near visual acuity
Popis výsledku anglicky
In a low-cost laboratory setup, we compared visual acuity (VA) for stimuli rendered with Zernike aberrations to an equivalent optical dioptric defocus in emmetropic individuals using a relatively short observing distance of 60 cm. The equivalent spherical refractive error of+ 1, + 2 or + 4 D, was applied in the rendering of Landolt Rings. Separately, the refractive error was introduced dioptrically in: (1) unchanged Landolt Rings with an added external lens (+1, + 2 or + 4 D) at the subject's eye; (2) same as (1) but with an added accommodation and a vertex distance adjustment. To compare all three approaches, we examined VA in 10 healthy men. Stimuli were observed on a PC CRT screen. For all three levels of refractive error, the pairwise comparison did not show a statistically signifcant diference between digital blur and accommodation-plus-vertex-distance-adjusted dioptric blur (p< 0.204). The best agreement, determined by Bland-Altman analysis, was measured for+ 4 D and was in line with test-retest limits for examination in the clinical population. Our results show that even for a near observing distance, it is possible to use digitally rendered defocus to replicate dioptric blur without a signifcant change in VA in emmetropic subjects.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
<a href="/cs/project/NV18-06-00484" target="_blank" >NV18-06-00484: Zlepšení kvality života u pacientů se stabilní makulopatií prostřednictvím implantace intraokulární makulární čočky a modulací zrakové plasticity transkraniální elektrickou stimulací</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Reports
ISSN
2045-2322
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
3437
Kód UT WoS článku
000625195000001
EID výsledku v databázi Scopus
2-s2.0-85100701296