Myocardial injury in stress echocardiography: Comparison of dobutamine, dipyridamole and dynamic stressors-single center study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F22%3A10449430" target="_blank" >RIV/00216208:11150/22:10449430 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00179906:_____/22:10449430 RIV/00216224:14110/22:00128278
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ttoTGG2TQe" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ttoTGG2TQe</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/echo.15411" target="_blank" >10.1111/echo.15411</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Myocardial injury in stress echocardiography: Comparison of dobutamine, dipyridamole and dynamic stressors-single center study
Popis výsledku v původním jazyce
Objectives: In stress echocardiography (SE), dipyridamole (DIP) and dynamic stress (ExSE) are reported as being safer than dobutamine stress echocardiography (DSE). We investigated whether these commonly used stressors cause myocardial injury, measured by high sensitivity troponin T (hsTnT). Methods: One hundred and thirty five patients (DSE n = 46, ExsE n = 46, DIP n = 43) with negative result of SE were studied. The exclusion criteria were known ischaemic heart disease (IHD), baseline wall motion abnormalities, left ventricle systolic dysfunction/regional wall motion abnormalities, septum/posterior wall >= 13 mm, diabetes/pre-diabetes, baseline hsTnT level >= 14 ng/L, baseline blood pressure >= 160/100 mmHg, peak pulmonary pressure >= 45mmHg, eGFR <1ml/s/1.73m(2), more than mild to moderate valvular disease and dobutamine side effects. HsTnT was measured before and 180 minutes after the test. Results: All patients had low pre-test probabilities of having obstructive IHD. HsTnT increased in DSE, less so in ExSE, and was unchanged in the DIP group (Delta hsTnT 9.4 [1.5-58.6], 1.1 [-0.9-15.7], -0.1 [-1.4-2.1] ng/L, respectively, p<0.001). In DSE, the Delta hsTnT was associated with peak dobutamine dose (r = 0.30, p = 0.045), test length (r = 0.43, p = 0.003) and atropine use (p<0.001). In ExSE, the hsTnT increase was more likely in females (p = 0.012) and the elderly (>65 years) (r = 0.32, p = 0.03); no association was found between atropine use (p = 0.786) or test length and AhsTnT (r = 0.10, p = 0.530). Conclusions: DSE is associated with myocardial injury in patients with negative SE, no injury was observed in DIP and only mild case in ExSE. Whether myocardial injury is causative of the higher reported adverse event rates in DSE remains to be determined.
Název v anglickém jazyce
Myocardial injury in stress echocardiography: Comparison of dobutamine, dipyridamole and dynamic stressors-single center study
Popis výsledku anglicky
Objectives: In stress echocardiography (SE), dipyridamole (DIP) and dynamic stress (ExSE) are reported as being safer than dobutamine stress echocardiography (DSE). We investigated whether these commonly used stressors cause myocardial injury, measured by high sensitivity troponin T (hsTnT). Methods: One hundred and thirty five patients (DSE n = 46, ExsE n = 46, DIP n = 43) with negative result of SE were studied. The exclusion criteria were known ischaemic heart disease (IHD), baseline wall motion abnormalities, left ventricle systolic dysfunction/regional wall motion abnormalities, septum/posterior wall >= 13 mm, diabetes/pre-diabetes, baseline hsTnT level >= 14 ng/L, baseline blood pressure >= 160/100 mmHg, peak pulmonary pressure >= 45mmHg, eGFR <1ml/s/1.73m(2), more than mild to moderate valvular disease and dobutamine side effects. HsTnT was measured before and 180 minutes after the test. Results: All patients had low pre-test probabilities of having obstructive IHD. HsTnT increased in DSE, less so in ExSE, and was unchanged in the DIP group (Delta hsTnT 9.4 [1.5-58.6], 1.1 [-0.9-15.7], -0.1 [-1.4-2.1] ng/L, respectively, p<0.001). In DSE, the Delta hsTnT was associated with peak dobutamine dose (r = 0.30, p = 0.045), test length (r = 0.43, p = 0.003) and atropine use (p<0.001). In ExSE, the hsTnT increase was more likely in females (p = 0.012) and the elderly (>65 years) (r = 0.32, p = 0.03); no association was found between atropine use (p = 0.786) or test length and AhsTnT (r = 0.10, p = 0.530). Conclusions: DSE is associated with myocardial injury in patients with negative SE, no injury was observed in DIP and only mild case in ExSE. Whether myocardial injury is causative of the higher reported adverse event rates in DSE remains to be determined.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Echocardiography
ISSN
0742-2822
e-ISSN
1540-8175
Svazek periodika
39
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
1171-1179
Kód UT WoS článku
000838624800001
EID výsledku v databázi Scopus
2-s2.0-85135837175