Sequential injection determination of orthophosphate as ion associate of 12-molybdophosphate with Astra Phloxine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F11%3A10100197" target="_blank" >RIV/00216208:11160/11:10100197 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0039914011001998" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0039914011001998</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2011.02.046" target="_blank" >10.1016/j.talanta.2011.02.046</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sequential injection determination of orthophosphate as ion associate of 12-molybdophosphate with Astra Phloxine
Popis výsledku v původním jazyce
A simple and fast reaction between 12-molybdophosphate heteropoly anion and the polymethine dye Astra Phloxine was used for the development of a new SIA method for the determination of orthophosphate. The suggested method has higher sensitivity and a broader calibration range than existing SIA methods. It can be used to detect phosphate in the range from 0.2 to 10 mu mol L(-1) with a detection limit of 0.1 mu mol L(-1) and an acceptable throughput of 20 samples h(-1). The comparably low molybdate (5.6 mmol L(-1)) and dye (0.1 mmol L(-1)) concentrations led to an improvement in the stability of the base line. Inter-day reproducibility was better than 5%, while the intra-day RSD was in the range 0.8-3.5%. The method was used for the analysis of natural water samples and phosphorus-containing chemicals having a low content of orthophosphate.
Název v anglickém jazyce
Sequential injection determination of orthophosphate as ion associate of 12-molybdophosphate with Astra Phloxine
Popis výsledku anglicky
A simple and fast reaction between 12-molybdophosphate heteropoly anion and the polymethine dye Astra Phloxine was used for the development of a new SIA method for the determination of orthophosphate. The suggested method has higher sensitivity and a broader calibration range than existing SIA methods. It can be used to detect phosphate in the range from 0.2 to 10 mu mol L(-1) with a detection limit of 0.1 mu mol L(-1) and an acceptable throughput of 20 samples h(-1). The comparably low molybdate (5.6 mmol L(-1)) and dye (0.1 mmol L(-1)) concentrations led to an improvement in the stability of the base line. Inter-day reproducibility was better than 5%, while the intra-day RSD was in the range 0.8-3.5%. The method was used for the analysis of natural water samples and phosphorus-containing chemicals having a low content of orthophosphate.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FR - Farmakologie a lékárnická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
84
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
1355-1360
Kód UT WoS článku
000292475600027
EID výsledku v databázi Scopus
—