Circumventing the requirement of binding saturation for receptor quantification using interaction kinetic extrapolation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F11%3A10118908" target="_blank" >RIV/00216208:11160/11:10118908 - isvavai.cz</a>
Výsledek na webu
<a href="http://ovidsp.tx.ovid.com/sp-3.5.1a/ovidweb.cgi?T=JS&PAGE=fulltext&D=ovft&AN=00006231-201109000-00015&NEWS=N" target="_blank" >http://ovidsp.tx.ovid.com/sp-3.5.1a/ovidweb.cgi?T=JS&PAGE=fulltext&D=ovft&AN=00006231-201109000-00015&NEWS=N</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/MNM.0b013e3283483e1c" target="_blank" >10.1097/MNM.0b013e3283483e1c</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Circumventing the requirement of binding saturation for receptor quantification using interaction kinetic extrapolation
Popis výsledku v původním jazyce
Quantification of the number of receptors per cell (NRPC) is important when assessing whether a tumor surface biomarker is suitable for medical imaging. One common method for NPRC quantification is to use a binding saturation assay, which is time consuming and requires large amounts of reagents. The aim of this study was to evaluate an alternative method based on kinetic extrapolation (KEX) and compare it with the classical manual saturation technique with regard to accuracy as well as time and reagentconsumption. From the observations described in this study, we believe that the KEX method enables fast, credible, and easy NRPC quantification with a reduction in reagent consumption.
Název v anglickém jazyce
Circumventing the requirement of binding saturation for receptor quantification using interaction kinetic extrapolation
Popis výsledku anglicky
Quantification of the number of receptors per cell (NRPC) is important when assessing whether a tumor surface biomarker is suitable for medical imaging. One common method for NPRC quantification is to use a binding saturation assay, which is time consuming and requires large amounts of reagents. The aim of this study was to evaluate an alternative method based on kinetic extrapolation (KEX) and compare it with the classical manual saturation technique with regard to accuracy as well as time and reagentconsumption. From the observations described in this study, we believe that the KEX method enables fast, credible, and easy NRPC quantification with a reduction in reagent consumption.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FR - Farmakologie a lékárnická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Medicine Communications
ISSN
0143-3636
e-ISSN
—
Svazek periodika
32
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
863-867
Kód UT WoS článku
000294345300015
EID výsledku v databázi Scopus
—