Determination of phenolic acids in plant extracts using CZE with on-line transient isotachophoretic preconcentration
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F13%3A10145913" target="_blank" >RIV/00216208:11160/13:10145913 - isvavai.cz</a>
Výsledek na webu
<a href="http://onlinelibrary.wiley.com/doi/10.1002/jssc.201200806/full" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/jssc.201200806/full</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jssc.201200806" target="_blank" >10.1002/jssc.201200806</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of phenolic acids in plant extracts using CZE with on-line transient isotachophoretic preconcentration
Popis výsledku v původním jazyce
A novel transient ITP-CZE for preconcentration and determination of seven phenolic acids (caffeic acid, cinnamic acid, p-coumaric acid, ferulic acid, protocatechuic acid, syringic acid, and vanilic acid) was developed and validated. Effects of several factors such as control of EOF, pH and buffer concentration, addition of organic solvents and CDs, and conditions for sample injection were investigated. Sample self-stacking was applied by means of induction of transient ITP, which was realized by addingsodium chloride into the sample. The CZE was realized in 200 mM borate buffer ((s)(w)pH 9.2) containing 37.5% methanol, 0.001% hexadimethrine bromide, and 15 mM 2-hydroxypropyl-beta-CD. Under the optimal conditions for analysis, analytes were separated within 20 min. Linearity was tested for each compound in the concentration range of 0.1-10 mu g/mL (R = 0.9906-0.9968) and the detection limits (S/N = 3) ranged from 11 ng/mL (protocatechuic acid) to 31 mu g/mL (syringic acid). The validat
Název v anglickém jazyce
Determination of phenolic acids in plant extracts using CZE with on-line transient isotachophoretic preconcentration
Popis výsledku anglicky
A novel transient ITP-CZE for preconcentration and determination of seven phenolic acids (caffeic acid, cinnamic acid, p-coumaric acid, ferulic acid, protocatechuic acid, syringic acid, and vanilic acid) was developed and validated. Effects of several factors such as control of EOF, pH and buffer concentration, addition of organic solvents and CDs, and conditions for sample injection were investigated. Sample self-stacking was applied by means of induction of transient ITP, which was realized by addingsodium chloride into the sample. The CZE was realized in 200 mM borate buffer ((s)(w)pH 9.2) containing 37.5% methanol, 0.001% hexadimethrine bromide, and 15 mM 2-hydroxypropyl-beta-CD. Under the optimal conditions for analysis, analytes were separated within 20 min. Linearity was tested for each compound in the concentration range of 0.1-10 mu g/mL (R = 0.9906-0.9968) and the detection limits (S/N = 3) ranged from 11 ng/mL (protocatechuic acid) to 31 mu g/mL (syringic acid). The validat
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Separation Science
ISSN
1615-9306
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
729-735
Kód UT WoS článku
000319862400012
EID výsledku v databázi Scopus
—