Automated in-syringe single-drop head-space micro-extraction applied to the determination of ethanol in wine samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F14%3A10281833" target="_blank" >RIV/00216208:11160/14:10281833 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0003267014004693" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0003267014004693</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2014.04.031" target="_blank" >10.1016/j.aca.2014.04.031</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Automated in-syringe single-drop head-space micro-extraction applied to the determination of ethanol in wine samples
Popis výsledku v původním jazyce
A novel approach of head-space single-drop micro-extraction applied to the determination of ethanol in wine is presented. For the first time, the syringe of an automated syringe pump was used as an extraction chamber of adaptable size for a volatile analyte. This approach enabled to apply negative pressure during the enrichment step, which favored the evaporation of the analyte. Placing a slowly spinning magnetic stirring bar inside the syringe, effective syringe cleaning as well as mixing of the samplewith buffer solution to suppress the interference of acetic acid was achieved. Ethanol determination was based on the reduction of a single drop of 3 mmol L-1 potassium dichromate dissolved in 8 mol L-1 sulfuric acid. The drop was positioned in the syringe inlet in the head-space above the sample with posterior spectrophotometric quantification. The entire procedure was carried out automatically using a simple sequential injection analyzer system. One analysis required less than 5 min i
Název v anglickém jazyce
Automated in-syringe single-drop head-space micro-extraction applied to the determination of ethanol in wine samples
Popis výsledku anglicky
A novel approach of head-space single-drop micro-extraction applied to the determination of ethanol in wine is presented. For the first time, the syringe of an automated syringe pump was used as an extraction chamber of adaptable size for a volatile analyte. This approach enabled to apply negative pressure during the enrichment step, which favored the evaporation of the analyte. Placing a slowly spinning magnetic stirring bar inside the syringe, effective syringe cleaning as well as mixing of the samplewith buffer solution to suppress the interference of acetic acid was achieved. Ethanol determination was based on the reduction of a single drop of 3 mmol L-1 potassium dichromate dissolved in 8 mol L-1 sulfuric acid. The drop was positioned in the syringe inlet in the head-space above the sample with posterior spectrophotometric quantification. The entire procedure was carried out automatically using a simple sequential injection analyzer system. One analysis required less than 5 min i
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0022" target="_blank" >EE2.3.30.0022: Podpora vytváření, rozvoje a mobility kvalitních výzkumně-vývojových týmů na Univerzitě Karlově</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
—
Svazek periodika
828
Číslo periodika v rámci svazku
May
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
53-60
Kód UT WoS článku
000336336900007
EID výsledku v databázi Scopus
—