A novel approach to Lab-In-Syringe Head-Space Single-Drop Microextraction and on-drop sensing of ammonia
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F16%3A10326194" target="_blank" >RIV/00216208:11160/16:10326194 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0003267016308029" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0003267016308029</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2016.06.039" target="_blank" >10.1016/j.aca.2016.06.039</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A novel approach to Lab-In-Syringe Head-Space Single-Drop Microextraction and on-drop sensing of ammonia
Popis výsledku v původním jazyce
A novel approach to the automation technique Lab-In-Syringe, also known as In-Syringe Analysis, is proposed which utilizes a secondary inlet into the syringe void, used as a size-adaptable reaction chamber, via a channel passing through the syringe piston. This innovative approach allows straightforward automation of head-space single-drop microextraction, involving accurately controlled drop formation and handling, and the possibility of on-drop analyte quantification. The syringe was used in upside-down orientation and in-syringe magnetic stirring was carried out, which allowed homogenous mixing of solutions, promotion of head-space analyte enrichment, and efficient syringe cleaning. The superior performance of the newly developed system was illustrated with the development of a sensitive method for total ammonia determination in surface waters. It is based on head-space extraction of ammonia into a single drop of bromothymol blue indicator created inside the syringe at the orifice of the syringe piston channel and on-drop sensing of the color change via fiber optics. The slope of the linear relationship between absorbance and time was used as the analytical signal. Drop formation and performance of on-drop monitoring was further studied with rhodamine B solution to give a better understanding of the system's performance. A repeatability of 6% RSD at 10 micromol L-1 NH3, a linear range of up to 25 micromol L-1 NH3, and a limit of detection of 1.8 micromol L-1 NH3 were achieved. Study of interferences proved the high robustness of the method towards humic acids, high sample salinity, and the presence of detergents, thus demonstrating the method superiority compared to the state-of-the-art gas-diffusion methods. A mean analyte recovery of 101.8% was found in analyzing spiked environmental water samples.
Název v anglickém jazyce
A novel approach to Lab-In-Syringe Head-Space Single-Drop Microextraction and on-drop sensing of ammonia
Popis výsledku anglicky
A novel approach to the automation technique Lab-In-Syringe, also known as In-Syringe Analysis, is proposed which utilizes a secondary inlet into the syringe void, used as a size-adaptable reaction chamber, via a channel passing through the syringe piston. This innovative approach allows straightforward automation of head-space single-drop microextraction, involving accurately controlled drop formation and handling, and the possibility of on-drop analyte quantification. The syringe was used in upside-down orientation and in-syringe magnetic stirring was carried out, which allowed homogenous mixing of solutions, promotion of head-space analyte enrichment, and efficient syringe cleaning. The superior performance of the newly developed system was illustrated with the development of a sensitive method for total ammonia determination in surface waters. It is based on head-space extraction of ammonia into a single drop of bromothymol blue indicator created inside the syringe at the orifice of the syringe piston channel and on-drop sensing of the color change via fiber optics. The slope of the linear relationship between absorbance and time was used as the analytical signal. Drop formation and performance of on-drop monitoring was further studied with rhodamine B solution to give a better understanding of the system's performance. A repeatability of 6% RSD at 10 micromol L-1 NH3, a linear range of up to 25 micromol L-1 NH3, and a limit of detection of 1.8 micromol L-1 NH3 were achieved. Study of interferences proved the high robustness of the method towards humic acids, high sample salinity, and the presence of detergents, thus demonstrating the method superiority compared to the state-of-the-art gas-diffusion methods. A mean analyte recovery of 101.8% was found in analyzing spiked environmental water samples.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-10781S" target="_blank" >GA15-10781S: On-line spojení automatizovaných extrakčních procesů s kapalinovou chromatografií pro kompletní analýzu vzorku</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
—
Svazek periodika
934
Číslo periodika v rámci svazku
August
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
13
Strana od-do
132-144
Kód UT WoS článku
000381928900016
EID výsledku v databázi Scopus
2-s2.0-84989825942