A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F14%3A10282243" target="_blank" >RIV/00216208:11160/14:10282243 - isvavai.cz</a>
Výsledek na webu
<a href="http://pubs.rsc.org/en/content/articlehtml/2014/ay/c3ay42200c" target="_blank" >http://pubs.rsc.org/en/content/articlehtml/2014/ay/c3ay42200c</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c3ay42200c" target="_blank" >10.1039/c3ay42200c</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine
Popis výsledku v původním jazyce
A new gradient reversed-phase HPLC method with pre-column derivatization was developed and validated for simultaneous determination of reduced glutathione, carnosine and taurine in new pharmaceutical eye drops. Chromatographic separation was achieved with a fused core analytical column Supelco Ascentis Express C18 (100 mm x 4.6 mm, 2.7 mu m). A 30 mM triethylamine in acetonitrile with 30 mM triethylamine aqueous solution (pH 2.5, adjusted with glacial acetic acid) was used in a gradient elution mode ata flow rate of 0.8 mL min(-1). The column temperature was maintained at 30 degrees C, the injection volume of the derivatized sample was 5 mu L and the detection wavelength was 375 nm. The tested validation parameters included system suitability, accuracy, precision, linearity, LOD, LOQ and sample solution stability. The standard calibration curves showed good linearity with correlation coefficients r > 0.997 for all compounds. The mean percentage recoveries obtained for reduced glutathi
Název v anglickém jazyce
A high-performance liquid chromatography method with pre-column derivatization for the simultaneous determination of reduced glutathione, carnosine and taurine
Popis výsledku anglicky
A new gradient reversed-phase HPLC method with pre-column derivatization was developed and validated for simultaneous determination of reduced glutathione, carnosine and taurine in new pharmaceutical eye drops. Chromatographic separation was achieved with a fused core analytical column Supelco Ascentis Express C18 (100 mm x 4.6 mm, 2.7 mu m). A 30 mM triethylamine in acetonitrile with 30 mM triethylamine aqueous solution (pH 2.5, adjusted with glacial acetic acid) was used in a gradient elution mode ata flow rate of 0.8 mL min(-1). The column temperature was maintained at 30 degrees C, the injection volume of the derivatized sample was 5 mu L and the detection wavelength was 375 nm. The tested validation parameters included system suitability, accuracy, precision, linearity, LOD, LOQ and sample solution stability. The standard calibration curves showed good linearity with correlation coefficients r > 0.997 for all compounds. The mean percentage recoveries obtained for reduced glutathi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.20.0235" target="_blank" >EE2.3.20.0235: Vybudování výzkumného týmu experimentální a aplikované biofarmacie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Methods
ISSN
1759-9660
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
1475-1481
Kód UT WoS článku
000332129500030