An on-line SPE-HPLC method for effective sample preconcentration and determination of fenoxycarb and cis, trans-permethrin in surface waters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F15%3A10312552" target="_blank" >RIV/00216208:11160/15:10312552 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S003991401500315X" target="_blank" >http://www.sciencedirect.com/science/article/pii/S003991401500315X</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2015.04.066" target="_blank" >10.1016/j.talanta.2015.04.066</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An on-line SPE-HPLC method for effective sample preconcentration and determination of fenoxycarb and cis, trans-permethrin in surface waters
Popis výsledku v původním jazyce
A new on-line SPE-HPLC method using fused-core columns for on-line solid phase extraction and large volume sample injection for increasing the sensitivity of detection was developed for the determination of insecticides fenoxycarb and cis-, trans-permethrin in surface waters. The separation was carried out on fused-core column Phenyl-Hexyl (100 x 4.6 mm), particle size 2.7 mu m with mobile phase acetonitrile: water in gradient mode at flow rate 1.0 mL min(-1), column temperature 45 degrees C. Large volume sample injection (1500 mu L) to the extraction dimension using short precolumn Ascentis Express RP C-18 (5 x 4.6 mm); fused-core particle size 2.7 mu m allowed effective sample preconcentration and efficient ballast sample matrix removal. The washingmobile phase consisting of a mixture of acetonitrile:water; 30:70, (v/v) was pumped at flow rate of 0.5 mL min(-1) through the extraction precolumn to the waste. Time of the valve switch for transferring the preconcentrated sample zone fr
Název v anglickém jazyce
An on-line SPE-HPLC method for effective sample preconcentration and determination of fenoxycarb and cis, trans-permethrin in surface waters
Popis výsledku anglicky
A new on-line SPE-HPLC method using fused-core columns for on-line solid phase extraction and large volume sample injection for increasing the sensitivity of detection was developed for the determination of insecticides fenoxycarb and cis-, trans-permethrin in surface waters. The separation was carried out on fused-core column Phenyl-Hexyl (100 x 4.6 mm), particle size 2.7 mu m with mobile phase acetonitrile: water in gradient mode at flow rate 1.0 mL min(-1), column temperature 45 degrees C. Large volume sample injection (1500 mu L) to the extraction dimension using short precolumn Ascentis Express RP C-18 (5 x 4.6 mm); fused-core particle size 2.7 mu m allowed effective sample preconcentration and efficient ballast sample matrix removal. The washingmobile phase consisting of a mixture of acetonitrile:water; 30:70, (v/v) was pumped at flow rate of 0.5 mL min(-1) through the extraction precolumn to the waste. Time of the valve switch for transferring the preconcentrated sample zone fr
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-10781S" target="_blank" >GA15-10781S: On-line spojení automatizovaných extrakčních procesů s kapalinovou chromatografií pro kompletní analýzu vzorku</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
142
Číslo periodika v rámci svazku
September
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
124-130
Kód UT WoS článku
000356997700017
EID výsledku v databázi Scopus
2-s2.0-84928949663