On-line coupling of Micro-Extraction by Packed Sorbent with Sequential Injection Chromatography system for direct extraction and determination of betaxolol in human urine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F15%3A10312647" target="_blank" >RIV/00216208:11160/15:10312647 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0039914015300035" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0039914015300035</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2015.05.048" target="_blank" >10.1016/j.talanta.2015.05.048</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On-line coupling of Micro-Extraction by Packed Sorbent with Sequential Injection Chromatography system for direct extraction and determination of betaxolol in human urine
Popis výsledku v původním jazyce
A novel approach for automation of Micro-Extraction by Packed Sorbent (MEPS), a solid phase extraction technique, is presented, enabling precise and repeatable liquid handling due to the employment of sequential injection technique. The developed systemwas used for human urine sample clean-up and pre-concentration of betaxolol before its separation and determination. A commercial MEPS C-18 cartridge Was integrated into an SIChrom (TM) system. The chromatographic separation was performed on a monolithicHigh Resolution C18 (50 x 4.6 mm) column which was coupled on-line in the system with Micro-Extraction using an additional selection valve. A mixture of acetonitrile and aqueous solution of 0.5% triethylamine with acetic acid, pH adjusted to 4.5 in ratio 30:70 was used as a mobile phase for elution of betaxolol from MEPS directly onto the monolithic column where the separation took place. Betaxolol was quantified by a fluorescence detector at wavelengths lambda(ex)= 220 nm and lambda(em
Název v anglickém jazyce
On-line coupling of Micro-Extraction by Packed Sorbent with Sequential Injection Chromatography system for direct extraction and determination of betaxolol in human urine
Popis výsledku anglicky
A novel approach for automation of Micro-Extraction by Packed Sorbent (MEPS), a solid phase extraction technique, is presented, enabling precise and repeatable liquid handling due to the employment of sequential injection technique. The developed systemwas used for human urine sample clean-up and pre-concentration of betaxolol before its separation and determination. A commercial MEPS C-18 cartridge Was integrated into an SIChrom (TM) system. The chromatographic separation was performed on a monolithicHigh Resolution C18 (50 x 4.6 mm) column which was coupled on-line in the system with Micro-Extraction using an additional selection valve. A mixture of acetonitrile and aqueous solution of 0.5% triethylamine with acetic acid, pH adjusted to 4.5 in ratio 30:70 was used as a mobile phase for elution of betaxolol from MEPS directly onto the monolithic column where the separation took place. Betaxolol was quantified by a fluorescence detector at wavelengths lambda(ex)= 220 nm and lambda(em
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-10781S" target="_blank" >GA15-10781S: On-line spojení automatizovaných extrakčních procesů s kapalinovou chromatografií pro kompletní analýzu vzorku</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
143
Číslo periodika v rámci svazku
October
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
132-137
Kód UT WoS článku
000357750200020
EID výsledku v databázi Scopus
2-s2.0-84930653502