Development of matrix effect-free MISPE-UHPLC-MS/MS method for determination of lovastatin in Pu-erh tea, oyster mushroom, and red yeast rice
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F17%3A10365395" target="_blank" >RIV/00216208:11160/17:10365395 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0731708517304090" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0731708517304090</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jpba.2017.03.058" target="_blank" >10.1016/j.jpba.2017.03.058</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of matrix effect-free MISPE-UHPLC-MS/MS method for determination of lovastatin in Pu-erh tea, oyster mushroom, and red yeast rice
Popis výsledku v původním jazyce
Matrix effect-free UHPLC-MS/MS method was developed and validated for the determination of cholesterol-lowering lovastatin in food samples represented by Pu-erh tea, oyster mushroom, and red yeast rice. The resulting method was fully validated in terms of intra-day and inter-day precision, accuracy, linearity, range, LOD, LOQ and matrix effects. The matrix effect phenomenon evaluated by comparison of slopes of calibration curves was completely eliminated by solid-phase extraction based on the technique of molecularly imprinted polymers (MIPs). Comparison of elution profiles obtained on the MIP and corresponding control non-imprinted polymer (NIP) showed selectivity of the extraction procedure. In addition, selectivity of the MIP material and the molecularly imprinted solid-phase extraction (MISPE) was also proved by experiments evaluating retention of analytes physico-chemically similar to the target molecule. Extraction recoveries of these analytes represented by estrogen derivatives (estrone, estriol, 17 alpha-ethinylestradiol, and beta-estradiol) were very low or even null. Synthesis and preparation of the resulting MIP sorbent was characterized by excellent repeatability expressed as RSD 7.7% (n = 9) of extraction recoveries. The determined capacity of the MIP material reaching 375 ng/mg is sufficient for analysis of the evaluated statin in its natural sources. Suitability of the resulting MISPE-UHPLC-MS/MS procedure for real sample analysis was verified by the determination of lovastatin in one dietary supplement based on the red yeast rice with a given amount of the target analyte. Finally, three mushroom and fifteen tea samples obtained in Czech food stores and tearooms were subjected to analysis. Low or null amount of lovastatin was found in these samples.
Název v anglickém jazyce
Development of matrix effect-free MISPE-UHPLC-MS/MS method for determination of lovastatin in Pu-erh tea, oyster mushroom, and red yeast rice
Popis výsledku anglicky
Matrix effect-free UHPLC-MS/MS method was developed and validated for the determination of cholesterol-lowering lovastatin in food samples represented by Pu-erh tea, oyster mushroom, and red yeast rice. The resulting method was fully validated in terms of intra-day and inter-day precision, accuracy, linearity, range, LOD, LOQ and matrix effects. The matrix effect phenomenon evaluated by comparison of slopes of calibration curves was completely eliminated by solid-phase extraction based on the technique of molecularly imprinted polymers (MIPs). Comparison of elution profiles obtained on the MIP and corresponding control non-imprinted polymer (NIP) showed selectivity of the extraction procedure. In addition, selectivity of the MIP material and the molecularly imprinted solid-phase extraction (MISPE) was also proved by experiments evaluating retention of analytes physico-chemically similar to the target molecule. Extraction recoveries of these analytes represented by estrogen derivatives (estrone, estriol, 17 alpha-ethinylestradiol, and beta-estradiol) were very low or even null. Synthesis and preparation of the resulting MIP sorbent was characterized by excellent repeatability expressed as RSD 7.7% (n = 9) of extraction recoveries. The determined capacity of the MIP material reaching 375 ng/mg is sufficient for analysis of the evaluated statin in its natural sources. Suitability of the resulting MISPE-UHPLC-MS/MS procedure for real sample analysis was verified by the determination of lovastatin in one dietary supplement based on the red yeast rice with a given amount of the target analyte. Finally, three mushroom and fifteen tea samples obtained in Czech food stores and tearooms were subjected to analysis. Low or null amount of lovastatin was found in these samples.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Pharmaceutical and Biomedical Analysis
ISSN
0731-7085
e-ISSN
—
Svazek periodika
140
Číslo periodika v rámci svazku
June
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
367-376
Kód UT WoS článku
000402850500046
EID výsledku v databázi Scopus