In vitro assessment of polyethylene glycol and polyvinylpyrrolidone as hydrophilic additives on bioseparation by polysulfone membranes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F20%3A10417469" target="_blank" >RIV/00216208:11160/20:10417469 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=GnatlaOWBV" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=GnatlaOWBV</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10853-019-04123-1" target="_blank" >10.1007/s10853-019-04123-1</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In vitro assessment of polyethylene glycol and polyvinylpyrrolidone as hydrophilic additives on bioseparation by polysulfone membranes
Popis výsledku v původním jazyce
Considering the continuous increment of morbidity in patients with renal disease, the improvement of polymeric membranes characteristics for haemodialysis is a challenging issue. The efficient removal of middle size uremic toxins, as well as biocompatibility is crucial characteristics to ameliorate chronic kidney disease patients' outcomes. In this study, polysulfone membranes with different hydrophilic additives, molecular weight and concentrations were prepared by spin coating method, followed by phase inversion via immersion precipitation. The removal of urea, lysozyme and bovine serum albumin was studied using a miniaturized flow system, mimicking haemodialysis conditions. The optimal composition was 15.0 wt% of polysulfone and 2.5 wt% of polyvinylpyrrolidone K30. This selected membrane was fully permeable for urea, showed up to 50% rejection of lysozyme and very high rejection of albumin. The additive PVP K30 played important role in the improvement of porosity, without compromising the mechanical strength of the membrane. The biocompatibility of membrane was evaluated by material-induced haemolysis and platelet activation tests. The platelet activation and haemolysis were negligible, compared to other biocompatible materials. These results confirmed the haemocompatibility of the optimized membrane. Therefore, the membrane is not expected to modulate the biological response, when used for the haemodialysis treatment.
Název v anglickém jazyce
In vitro assessment of polyethylene glycol and polyvinylpyrrolidone as hydrophilic additives on bioseparation by polysulfone membranes
Popis výsledku anglicky
Considering the continuous increment of morbidity in patients with renal disease, the improvement of polymeric membranes characteristics for haemodialysis is a challenging issue. The efficient removal of middle size uremic toxins, as well as biocompatibility is crucial characteristics to ameliorate chronic kidney disease patients' outcomes. In this study, polysulfone membranes with different hydrophilic additives, molecular weight and concentrations were prepared by spin coating method, followed by phase inversion via immersion precipitation. The removal of urea, lysozyme and bovine serum albumin was studied using a miniaturized flow system, mimicking haemodialysis conditions. The optimal composition was 15.0 wt% of polysulfone and 2.5 wt% of polyvinylpyrrolidone K30. This selected membrane was fully permeable for urea, showed up to 50% rejection of lysozyme and very high rejection of albumin. The additive PVP K30 played important role in the improvement of porosity, without compromising the mechanical strength of the membrane. The biocompatibility of membrane was evaluated by material-induced haemolysis and platelet activation tests. The platelet activation and haemolysis were negligible, compared to other biocompatible materials. These results confirmed the haemocompatibility of the optimized membrane. Therefore, the membrane is not expected to modulate the biological response, when used for the haemodialysis treatment.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000841" target="_blank" >EF16_019/0000841: Zvýšení účinnosti a bezpečnosti léčiv a nutraceutik: moderní metody - nové výzvy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Materials Science
ISSN
0022-2461
e-ISSN
—
Svazek periodika
55
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
16
Strana od-do
1292-1307
Kód UT WoS článku
000490838300002
EID výsledku v databázi Scopus
2-s2.0-85074198502