Supercritical fluids in analysis of cannabinoids in various Cannabis products
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F22%3A10451106" target="_blank" >RIV/00216208:11160/22:10451106 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=z7fq4hF6ev" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=z7fq4hF6ev</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2022.340452" target="_blank" >10.1016/j.aca.2022.340452</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Supercritical fluids in analysis of cannabinoids in various Cannabis products
Popis výsledku v původním jazyce
We developed a fast, selective, and sensitive method for the determination of various neutral and acidic phytocannabinoids with an emphasis on the separation of structurally related compounds. Optimized ultra-high performance supercritical fluid chromatography (UHPSFC) allowed the separation of 2 groups of structural isomers, including isomers of m/z 357: cannabidiolic and Delta(9)-tetrahydrocannabinolic acid, and isomers of m/z 315: cannabichromene, Delta(9)-tetrahydrocannabinol, Delta(8)-tetrahydrocannabinol, cannabicyclol, and cannabidiol only in mere 3.5 min followed by 1.5 min equlibration. The 2-ethylpyridine functionalized stationary phase and gradient elution using mobile phase comprising carbon dioxide and methanol: acetonitrile (25:75) + 5% water mixture were selected after the optimization. Tandem mass spectrometry (MS/MS) with electrospray ionization in positive and negative modes with methanol + 5% water as a make-up solvent provided adequate selectivity and sensitivity needed for analysis of phytocannabinoids in complex matrices. The limits of quantification were in the range 0.01-0.5 ng/mL for most of the monitored cannabinoids. The optimized UHPSFC-MS/MS method was then used for the determination of cannabinoids in various products, such as dietary supplements, nutraceuticals, and cosmetics. Solvent extraction methods were optimized for the cosmetic and nutraceutical products with the accuracy in the range 80.4-120.6% and precision 0.5-18.9%. To extract cannabinoids from the herbal infusion matrix, supercritical fluid extraction (SFE) and pressurized liquid extraction (PLE) methods were developed using environmentally friendly solvents water, ethanol, and carbon dioxide. The detailed optimization of extraction solvent composition, temperature, and pressure was carried out with the emphasis on avoiding the thermal degradation of cannabinoids. Optimized SFE and PLE methods were compared and applied to different herbal infusions to confirm declared cannabinoids content.
Název v anglickém jazyce
Supercritical fluids in analysis of cannabinoids in various Cannabis products
Popis výsledku anglicky
We developed a fast, selective, and sensitive method for the determination of various neutral and acidic phytocannabinoids with an emphasis on the separation of structurally related compounds. Optimized ultra-high performance supercritical fluid chromatography (UHPSFC) allowed the separation of 2 groups of structural isomers, including isomers of m/z 357: cannabidiolic and Delta(9)-tetrahydrocannabinolic acid, and isomers of m/z 315: cannabichromene, Delta(9)-tetrahydrocannabinol, Delta(8)-tetrahydrocannabinol, cannabicyclol, and cannabidiol only in mere 3.5 min followed by 1.5 min equlibration. The 2-ethylpyridine functionalized stationary phase and gradient elution using mobile phase comprising carbon dioxide and methanol: acetonitrile (25:75) + 5% water mixture were selected after the optimization. Tandem mass spectrometry (MS/MS) with electrospray ionization in positive and negative modes with methanol + 5% water as a make-up solvent provided adequate selectivity and sensitivity needed for analysis of phytocannabinoids in complex matrices. The limits of quantification were in the range 0.01-0.5 ng/mL for most of the monitored cannabinoids. The optimized UHPSFC-MS/MS method was then used for the determination of cannabinoids in various products, such as dietary supplements, nutraceuticals, and cosmetics. Solvent extraction methods were optimized for the cosmetic and nutraceutical products with the accuracy in the range 80.4-120.6% and precision 0.5-18.9%. To extract cannabinoids from the herbal infusion matrix, supercritical fluid extraction (SFE) and pressurized liquid extraction (PLE) methods were developed using environmentally friendly solvents water, ethanol, and carbon dioxide. The detailed optimization of extraction solvent composition, temperature, and pressure was carried out with the emphasis on avoiding the thermal degradation of cannabinoids. Optimized SFE and PLE methods were compared and applied to different herbal infusions to confirm declared cannabinoids content.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000841" target="_blank" >EF16_019/0000841: Zvýšení účinnosti a bezpečnosti léčiv a nutraceutik: moderní metody - nové výzvy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
1873-4324
Svazek periodika
1232
Číslo periodika v rámci svazku
November
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
12
Strana od-do
340452
Kód UT WoS článku
000872158600003
EID výsledku v databázi Scopus
2-s2.0-85139444500