Solvent-assisted dispersive micro-solid phase extraction of bisphenols using iron(III) thenoyltrifluoroacetonate complex (Fe(TTA)3) as a new nanostructured sorbent: a proof of concept
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F23%3A10471780" target="_blank" >RIV/00216208:11160/23:10471780 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/23:10471780
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=_qxhG-I6Hh" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=_qxhG-I6Hh</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/d3ay00214d" target="_blank" >10.1039/d3ay00214d</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Solvent-assisted dispersive micro-solid phase extraction of bisphenols using iron(III) thenoyltrifluoroacetonate complex (Fe(TTA)3) as a new nanostructured sorbent: a proof of concept
Popis výsledku v původním jazyce
In this work, we describe for the first time the use of iron(iii) thenoyltrifluoroacetonate complex (Fe(TTA)(3)) as a novel sorbent for solvent-assisted dispersive micro-solid phase extraction (SA-d mu SPE) of bisphenols from water samples. The extraction procedure is based on the formation of nanoparticles in situ following the rapid injection of a methanolic solution of Fe(TTA)(3) into the stirred aqueous sample. Herein, the synthesis of Fe(TTA)(3) and study of the essential parameters of the preparative procedure are described. The optimized procedure allowed for efficient enrichment of bisphenols from various water samples, chosen as model contaminants and matrix, within 2.5 min. The sorbent was collected by centrifugation, dissolved in methanol, and injected to perform HPLC with spectrophotometric detection. The limits of detection and quantification obtained ranged from 1.0-3.1 and 3.1-7.5 mu g L-1, respectively. Intraday and interday precisions of <7% relative standard deviation (RSD) and <8% RSD with analyte recoveries ranging between 70-117% (103.8% on average) were obtained for the analysis of river water, wastewater treatment plant effluent, and bottled water.
Název v anglickém jazyce
Solvent-assisted dispersive micro-solid phase extraction of bisphenols using iron(III) thenoyltrifluoroacetonate complex (Fe(TTA)3) as a new nanostructured sorbent: a proof of concept
Popis výsledku anglicky
In this work, we describe for the first time the use of iron(iii) thenoyltrifluoroacetonate complex (Fe(TTA)(3)) as a novel sorbent for solvent-assisted dispersive micro-solid phase extraction (SA-d mu SPE) of bisphenols from water samples. The extraction procedure is based on the formation of nanoparticles in situ following the rapid injection of a methanolic solution of Fe(TTA)(3) into the stirred aqueous sample. Herein, the synthesis of Fe(TTA)(3) and study of the essential parameters of the preparative procedure are described. The optimized procedure allowed for efficient enrichment of bisphenols from various water samples, chosen as model contaminants and matrix, within 2.5 min. The sorbent was collected by centrifugation, dissolved in methanol, and injected to perform HPLC with spectrophotometric detection. The limits of detection and quantification obtained ranged from 1.0-3.1 and 3.1-7.5 mu g L-1, respectively. Intraday and interday precisions of <7% relative standard deviation (RSD) and <8% RSD with analyte recoveries ranging between 70-117% (103.8% on average) were obtained for the analysis of river water, wastewater treatment plant effluent, and bottled water.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000841" target="_blank" >EF16_019/0000841: Zvýšení účinnosti a bezpečnosti léčiv a nutraceutik: moderní metody - nové výzvy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Methods
ISSN
1759-9660
e-ISSN
1759-9679
Svazek periodika
15
Číslo periodika v rámci svazku
17
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
2061-2072
Kód UT WoS článku
000949627600001
EID výsledku v databázi Scopus
2-s2.0-85151038782