Lab-in-syringe automated dispersive solid-phase microextraction of alkylphenols coupled online to liquid chromatography using iron(III) thenoyltrifluoroacetonate as dissolvable sorbent
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F25%3A10500900" target="_blank" >RIV/00216208:11160/25:10500900 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=qXXQOhe-MN" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=qXXQOhe-MN</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2025.343764" target="_blank" >10.1016/j.aca.2025.343764</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lab-in-syringe automated dispersive solid-phase microextraction of alkylphenols coupled online to liquid chromatography using iron(III) thenoyltrifluoroacetonate as dissolvable sorbent
Popis výsledku v původním jazyce
Background: Alkylphenols are water contaminants of strong endocrine disruptive potential. Sample preparation is generally imperative to improve sensitivity and minimize matrix effects. Dispersive solid phase extraction is a powerful alternative to cartridge-based sorbent extraction omitting backpressure problems and reducing procedural time. Herein, solvent-dissolvable sorbents offer the advantages of easy and cost-efficient production, efficiency, and full analyte recovery, while eluates can be directly submitted to instrumental determination. Despite the potential to reduce environmental impact and enhance reproducibility, there is a lack of automation attempts. Results: A fully automated solvent-assisted dispersive solid phase extraction method was developed for selected alkylphenols based on the technique Lab-In-Syringe. The void of automatic bidirectional syringe pump was used as mixing and extraction vessel. The iron(III) thenoyltrifluoroacetonate complex was used as novel dissolvable sorbent. 40 mu L complex solution was dispersed in the sample, leading to the precipitation of 0.4 mg sorbent. Extraction occurred within 40 s and was accelerated by in-syringe magnetic stirring. The sorbent was retained on a melamine foam packing in the syringe inlet, dissolved in a methanolic solution of ascorbic acid, and injected into online-coupled HPLC. Linear working ranges were achieved from 1 to 1000 mu g/L with sub-ppb detection limits and accuracies ranging from 98.3 to 110 %. Significance: In this work, we explored for the first time automated in-syringe automated dispersive SPE based on a dissolvable sorbent. Parallel operation of sample pretreatment and separation enabled throughputs of 4.5/h with typically <5 % RSD and preconcentrations of 16.4-21.2. AGREE greenness evaluation yielded a score of 0.59.
Název v anglickém jazyce
Lab-in-syringe automated dispersive solid-phase microextraction of alkylphenols coupled online to liquid chromatography using iron(III) thenoyltrifluoroacetonate as dissolvable sorbent
Popis výsledku anglicky
Background: Alkylphenols are water contaminants of strong endocrine disruptive potential. Sample preparation is generally imperative to improve sensitivity and minimize matrix effects. Dispersive solid phase extraction is a powerful alternative to cartridge-based sorbent extraction omitting backpressure problems and reducing procedural time. Herein, solvent-dissolvable sorbents offer the advantages of easy and cost-efficient production, efficiency, and full analyte recovery, while eluates can be directly submitted to instrumental determination. Despite the potential to reduce environmental impact and enhance reproducibility, there is a lack of automation attempts. Results: A fully automated solvent-assisted dispersive solid phase extraction method was developed for selected alkylphenols based on the technique Lab-In-Syringe. The void of automatic bidirectional syringe pump was used as mixing and extraction vessel. The iron(III) thenoyltrifluoroacetonate complex was used as novel dissolvable sorbent. 40 mu L complex solution was dispersed in the sample, leading to the precipitation of 0.4 mg sorbent. Extraction occurred within 40 s and was accelerated by in-syringe magnetic stirring. The sorbent was retained on a melamine foam packing in the syringe inlet, dissolved in a methanolic solution of ascorbic acid, and injected into online-coupled HPLC. Linear working ranges were achieved from 1 to 1000 mu g/L with sub-ppb detection limits and accuracies ranging from 98.3 to 110 %. Significance: In this work, we explored for the first time automated in-syringe automated dispersive SPE based on a dissolvable sorbent. Parallel operation of sample pretreatment and separation enabled throughputs of 4.5/h with typically <5 % RSD and preconcentrations of 16.4-21.2. AGREE greenness evaluation yielded a score of 0.59.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
1873-4324
Svazek periodika
1345
Číslo periodika v rámci svazku
April
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
11
Strana od-do
343764
Kód UT WoS článku
001424888500001
EID výsledku v databázi Scopus
2-s2.0-85216879687