Flow analysis-solid phase extraction system and UHPLC-MS/MS analytical methodology for the determination of antiviral drugs in surface water
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F24%3A10487536" target="_blank" >RIV/00216208:11160/24:10487536 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=dRVEMHprVi" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=dRVEMHprVi</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s11356-024-34466-5" target="_blank" >10.1007/s11356-024-34466-5</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Flow analysis-solid phase extraction system and UHPLC-MS/MS analytical methodology for the determination of antiviral drugs in surface water
Popis výsledku v původním jazyce
An automated flow analysis-solid phase extraction (FA-SPE) system and methodology of ultra-high-performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) analysis were developed for the determination of selected antiviral drugs (acyclovir, amantadine, rimantadine, and oseltamivir) in water samples. The proposed FA-SPE approach enables the integration of various extraction stages and elimination of the sample evaporation step and offers individual customisation of SPE parameters, inter alia sample, and eluate flow rate and volume. Using the developed FA-SPE procedure, e.g. a 100-fold preconcentration of the target analytes in 1 h was achieved. A method for chromatographic analysis was also developed to determine the selected antiviral drugs in combination with the use of the FA-SPE system. The developed FA-SPE UHPLC-MS/MS method was validated including the determination of linearity of analytical graphs, limits of detection (5.5-99.9 pg mL-1) and quantification (18.3-329.8 pg mL-1), intra-day (1.8-8.3%) and inter-day (3.0-9.2%) precision, recovery (95.6-105.3%), and matrix effects (-12.9 to 13.2%). The proposed method was successfully applied to analyse tap, drinking, and river water samples, revealing the presence of amantadine at a concentration of 40.1 pg mL-1 in one sample. The environmental impact of the developed FA-SPE sample preparation procedure was also assessed using the AGREEprep metric tool and compared with five other literature methods, achieving the most sustainable outcome.
Název v anglickém jazyce
Flow analysis-solid phase extraction system and UHPLC-MS/MS analytical methodology for the determination of antiviral drugs in surface water
Popis výsledku anglicky
An automated flow analysis-solid phase extraction (FA-SPE) system and methodology of ultra-high-performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) analysis were developed for the determination of selected antiviral drugs (acyclovir, amantadine, rimantadine, and oseltamivir) in water samples. The proposed FA-SPE approach enables the integration of various extraction stages and elimination of the sample evaporation step and offers individual customisation of SPE parameters, inter alia sample, and eluate flow rate and volume. Using the developed FA-SPE procedure, e.g. a 100-fold preconcentration of the target analytes in 1 h was achieved. A method for chromatographic analysis was also developed to determine the selected antiviral drugs in combination with the use of the FA-SPE system. The developed FA-SPE UHPLC-MS/MS method was validated including the determination of linearity of analytical graphs, limits of detection (5.5-99.9 pg mL-1) and quantification (18.3-329.8 pg mL-1), intra-day (1.8-8.3%) and inter-day (3.0-9.2%) precision, recovery (95.6-105.3%), and matrix effects (-12.9 to 13.2%). The proposed method was successfully applied to analyse tap, drinking, and river water samples, revealing the presence of amantadine at a concentration of 40.1 pg mL-1 in one sample. The environmental impact of the developed FA-SPE sample preparation procedure was also assessed using the AGREEprep metric tool and compared with five other literature methods, achieving the most sustainable outcome.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Environmental Science and Pollution Research
ISSN
0944-1344
e-ISSN
1614-7499
Svazek periodika
31
Číslo periodika v rámci svazku
37
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
14
Strana od-do
49546-49559
Kód UT WoS článku
999
EID výsledku v databázi Scopus
2-s2.0-85200030873