Deep eutectic solvent-based ferrofluid for vortex-assisted liquid-liquid microextraction of nonsteroidal anti-inflammatory drugs from environmental waters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F24%3A10487895" target="_blank" >RIV/00216208:11160/24:10487895 - isvavai.cz</a>
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=NmtK8huPyJ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=NmtK8huPyJ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2023.125372" target="_blank" >10.1016/j.talanta.2023.125372</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Deep eutectic solvent-based ferrofluid for vortex-assisted liquid-liquid microextraction of nonsteroidal anti-inflammatory drugs from environmental waters
Popis výsledku v původním jazyce
A novel ferrofluid of Fe3O4 nanoparticles and a deep eutectic solvent (DES) composed of menthol and pentanoic acid was introduced as a green microextraction medium. The ferrofluid was successfully used as an extractant for vortex-assisted liquid-liquid microextraction (VALLME) of nonsteroidal anti-inflammatory drugs (NSAIDs) in environmental waters prior to their determination by HPLC-DAD. Once the ferrofluid was dispersed in the sample by vortex agitation, phase separation could be easily achieved by placing a neodymium magnet next to the tube, which eliminated the centrifugation step and simplified the operational procedure. As a result, the sample pretreatment took only approximate to 2 min. The experimental parameters, including pH, nanoparticle amount, ferrofluid volume, vortex time, salt amount, and disruptive solvent type and its volume, were optimized stepwise. The method showed linear behavior for all NSAIDs from 5 to 100 mu g/L, with limit of detection values and enrichment factors in the ranges of 1.68-2.05 mu g/L and 38.9-50.6, respectively. Intra- and Inter-day accuracies obtained from the analysis of spiked river, lake, and tap water samples at low and high-quality control levels (20 and 80 mu g/L) ranged from 90.3% to 108.0%, with relative standard deviations less than <12.3%. The results of this study demonstrate that the use of DES-based ferrofluid in VALLME can be considered a simple, environmentally friendly, and reliable alternative for the determination of NSAIDs in environmental waters.
Název v anglickém jazyce
Deep eutectic solvent-based ferrofluid for vortex-assisted liquid-liquid microextraction of nonsteroidal anti-inflammatory drugs from environmental waters
Popis výsledku anglicky
A novel ferrofluid of Fe3O4 nanoparticles and a deep eutectic solvent (DES) composed of menthol and pentanoic acid was introduced as a green microextraction medium. The ferrofluid was successfully used as an extractant for vortex-assisted liquid-liquid microextraction (VALLME) of nonsteroidal anti-inflammatory drugs (NSAIDs) in environmental waters prior to their determination by HPLC-DAD. Once the ferrofluid was dispersed in the sample by vortex agitation, phase separation could be easily achieved by placing a neodymium magnet next to the tube, which eliminated the centrifugation step and simplified the operational procedure. As a result, the sample pretreatment took only approximate to 2 min. The experimental parameters, including pH, nanoparticle amount, ferrofluid volume, vortex time, salt amount, and disruptive solvent type and its volume, were optimized stepwise. The method showed linear behavior for all NSAIDs from 5 to 100 mu g/L, with limit of detection values and enrichment factors in the ranges of 1.68-2.05 mu g/L and 38.9-50.6, respectively. Intra- and Inter-day accuracies obtained from the analysis of spiked river, lake, and tap water samples at low and high-quality control levels (20 and 80 mu g/L) ranged from 90.3% to 108.0%, with relative standard deviations less than <12.3%. The results of this study demonstrate that the use of DES-based ferrofluid in VALLME can be considered a simple, environmentally friendly, and reliable alternative for the determination of NSAIDs in environmental waters.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000841" target="_blank" >EF16_019/0000841: Zvýšení účinnosti a bezpečnosti léčiv a nutraceutik: moderní metody - nové výzvy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
1873-3573
Svazek periodika
268
Číslo periodika v rámci svazku
February
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
125372
Kód UT WoS článku
001112205000001
EID výsledku v databázi Scopus
2-s2.0-85176295874