Voltammetric Determination of Azidothymidine Using Silver Solid Amalgam Electrodes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F09%3A10000209" target="_blank" >RIV/00216208:11310/09:10000209 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/09:00328330
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Determination of Azidothymidine Using Silver Solid Amalgam Electrodes
Popis výsledku v původním jazyce
A new simple and direct electroanalytical method was developed for the determination of azidothymidine in commercial pharmaceutical preparations. It is based on differential pulse voltammetry at silver solid amalgam electrode with polished surface (p-AgSAE) or surface modified by mercury meniscus (m-AgSAE). The electroreduction of azidothymidine in basic media at these electrodes gives rise to one irreversible cathodic peak. Its potential in 0.05 mol L-1 borate buffer, pH 9.3 at ca. - 1050 mV is comparable to that using hanging mercury drop electrode (HMDE). Achieved limits of quantitation are in the 10(-7) mol L-1 concentration range for both amalgam electrodes. According to the procedure based on the standard addition technique, the recoveries of known amounts of azidothymidine contained in pharmaceutical preparations available in capsules were 101.4 +/- 1.8% (m-AgSAE), 100.3 +/- 3.5% (p-AgSAE) and 102.0 +/- 1.0% (HMDE) (n = 10).
Název v anglickém jazyce
Voltammetric Determination of Azidothymidine Using Silver Solid Amalgam Electrodes
Popis výsledku anglicky
A new simple and direct electroanalytical method was developed for the determination of azidothymidine in commercial pharmaceutical preparations. It is based on differential pulse voltammetry at silver solid amalgam electrode with polished surface (p-AgSAE) or surface modified by mercury meniscus (m-AgSAE). The electroreduction of azidothymidine in basic media at these electrodes gives rise to one irreversible cathodic peak. Its potential in 0.05 mol L-1 borate buffer, pH 9.3 at ca. - 1050 mV is comparable to that using hanging mercury drop electrode (HMDE). Achieved limits of quantitation are in the 10(-7) mol L-1 concentration range for both amalgam electrodes. According to the procedure based on the standard addition technique, the recoveries of known amounts of azidothymidine contained in pharmaceutical preparations available in capsules were 101.4 +/- 1.8% (m-AgSAE), 100.3 +/- 3.5% (p-AgSAE) and 102.0 +/- 1.0% (HMDE) (n = 10).
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
15
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000268790300013
EID výsledku v databázi Scopus
—