Voltammetric determination of 2-amino-6-nitrobenzothiazole at two different silver amalgam electrodes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F12%3A10126403" target="_blank" >RIV/00216208:11310/12:10126403 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.electacta.2011.12.033" target="_blank" >http://dx.doi.org/10.1016/j.electacta.2011.12.033</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.electacta.2011.12.033" target="_blank" >10.1016/j.electacta.2011.12.033</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric determination of 2-amino-6-nitrobenzothiazole at two different silver amalgam electrodes
Popis výsledku v původním jazyce
Voltammetric behavior of genotoxic 2-amino-6-nitrobenzothiazole (ANBT) has been investigated using direct current voltammetry (DCV) and differential pulse voltammetry (DPV) at a polished silver solid amalgam electrode (p-AgSAE) and at a mercury meniscusmodified silver solid amalgam electrode (m-AgSAE). The optimum conditions have been found for its determination in the concentration range of 0.2-100 mu mol l(-1) in a 9:1 (v/v) mixture of aqueous Britton-Robinson buffer solution (pH 10.0) and methanol,with the limits of quantification (LQS) 0.10 mu mol l(-1) (DCV at p-AgSAE), 0.19 mu mol l(-1) (DPV at p-AgSAE), 0.17 mu mol l(-1) (DCV at m-AgSAE) and 0.12 mu mol l(-1) (DPV at m-AgSAE). An attempt at increasing the sensitivity using adsorptive strippingDCV or DPV at both p-AgSAE and m-AgSAE was not successful. Practical applicability of the newly developed methods was verified on direct determination of ANBT in spiked samples of drinking and river water, with LQS similar to 10(-7) mol
Název v anglickém jazyce
Voltammetric determination of 2-amino-6-nitrobenzothiazole at two different silver amalgam electrodes
Popis výsledku anglicky
Voltammetric behavior of genotoxic 2-amino-6-nitrobenzothiazole (ANBT) has been investigated using direct current voltammetry (DCV) and differential pulse voltammetry (DPV) at a polished silver solid amalgam electrode (p-AgSAE) and at a mercury meniscusmodified silver solid amalgam electrode (m-AgSAE). The optimum conditions have been found for its determination in the concentration range of 0.2-100 mu mol l(-1) in a 9:1 (v/v) mixture of aqueous Britton-Robinson buffer solution (pH 10.0) and methanol,with the limits of quantification (LQS) 0.10 mu mol l(-1) (DCV at p-AgSAE), 0.19 mu mol l(-1) (DPV at p-AgSAE), 0.17 mu mol l(-1) (DCV at m-AgSAE) and 0.12 mu mol l(-1) (DPV at m-AgSAE). An attempt at increasing the sensitivity using adsorptive strippingDCV or DPV at both p-AgSAE and m-AgSAE was not successful. Practical applicability of the newly developed methods was verified on direct determination of ANBT in spiked samples of drinking and river water, with LQS similar to 10(-7) mol
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrochimica Acta
ISSN
0013-4686
e-ISSN
—
Svazek periodika
62
Číslo periodika v rámci svazku
February
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
335-340
Kód UT WoS článku
000301096100046