Voltammetric determination of 4-nitrophenol and 5-nitrobenzimidazole using different types of silver solid amalgam electrodes - a comparative study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F11%3A10104926" target="_blank" >RIV/00216208:11310/11:10104926 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/11:00377570
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201100067" target="_blank" >http://dx.doi.org/10.1002/elan.201100067</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201100067" target="_blank" >10.1002/elan.201100067</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric determination of 4-nitrophenol and 5-nitrobenzimidazole using different types of silver solid amalgam electrodes - a comparative study
Popis výsledku v původním jazyce
The voltammetric behavior of two genotoxic nitro compounds (4-nitrophenol and 5-nitrobenzimidazole) has been investigated using direct current voltammetry (DCV) and differential pulse voltammetry (DPV) at a polished silver solid amalgam electrode (p-AgSAE), a mercury meniscus modified silver solid amalgam electrode (m-AgSAE), and a mercury film modified silver solid amalgam electrode (MF-AgSAE). The optimum conditions have been evaluated for their determination in Britton-Robinson buffer solutions. Thelimit of quantification (L(Q)) for 5-nitrobenzimidazole at p-AgSAE was 0.77 mu molL(-1) (DCV) and 0.47 mu molL(-1) (DPV), at m-AgSAE it was 0.32 mu molL(-1) (DCV) and 0.16 mu molL(-1) (DPV), and at MF-AgSAE it was 0.97 mu molL(-1) (DCV) and 0.70 mu molL(-1) (DPV). For 4-nitrophenol at p-AgSAE, L(Q) was 0.37 mu molL(-1) (DCV) and 0.32 mu molL(-1) (DPV), at m-AgSAE it was 0.14 mu molL(-1) (DCV) and 0.1 mu molL(-1) (DPV), and at MF-AgSAE, it was 0.87 mu molL(-1) (DCV) and 0.37 mu molL(-1) (
Název v anglickém jazyce
Voltammetric determination of 4-nitrophenol and 5-nitrobenzimidazole using different types of silver solid amalgam electrodes - a comparative study
Popis výsledku anglicky
The voltammetric behavior of two genotoxic nitro compounds (4-nitrophenol and 5-nitrobenzimidazole) has been investigated using direct current voltammetry (DCV) and differential pulse voltammetry (DPV) at a polished silver solid amalgam electrode (p-AgSAE), a mercury meniscus modified silver solid amalgam electrode (m-AgSAE), and a mercury film modified silver solid amalgam electrode (MF-AgSAE). The optimum conditions have been evaluated for their determination in Britton-Robinson buffer solutions. Thelimit of quantification (L(Q)) for 5-nitrobenzimidazole at p-AgSAE was 0.77 mu molL(-1) (DCV) and 0.47 mu molL(-1) (DPV), at m-AgSAE it was 0.32 mu molL(-1) (DCV) and 0.16 mu molL(-1) (DPV), and at MF-AgSAE it was 0.97 mu molL(-1) (DCV) and 0.70 mu molL(-1) (DPV). For 4-nitrophenol at p-AgSAE, L(Q) was 0.37 mu molL(-1) (DCV) and 0.32 mu molL(-1) (DPV), at m-AgSAE it was 0.14 mu molL(-1) (DCV) and 0.1 mu molL(-1) (DPV), and at MF-AgSAE, it was 0.87 mu molL(-1) (DCV) and 0.37 mu molL(-1) (
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
1548-1555
Kód UT WoS článku
000292967900006
EID výsledku v databázi Scopus
—