The Dependence of the Sensitivity and Reliability of Contactless Conductivity Detection on the Wall Thickness of Electrophoretic Fused-Silica Capillaries
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F09%3A10001397" target="_blank" >RIV/00216208:11310/09:10001397 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/09:00001668
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Dependence of the Sensitivity and Reliability of Contactless Conductivity Detection on the Wall Thickness of Electrophoretic Fused-Silica Capillaries
Popis výsledku v původním jazyce
A contactless conductivity detector (C4D) performance has been tested on a simple capillary electrophoretic separation in a standard fused-silica capillary with an external diameter of 360 ?m and in a thin-walled capillary (an external diameter of 150 ?m); the internal diameters of the two capillaries were identical, equal to 75 ?m. Potassium and sodium ions have been separated in a morpholinoethanesulfonic acid/histidine background electrolyte (MES/His), over a wide range of its concentrations (0 - 100mM). At low MES/His concentrations, the C4D response, obtained from the height of the potassium peak, is by 100 to 200 per cent higher for the thin-walled capillary and the calibration dependences are linear, in contrast to the thick-walled capillary. These differences between the two capillaries decrease with increasing MES/His concentration, the C4D response in the thin-walled capillary is then higher by mere 20 per cent and the calibration dependences are linear in both the capillari
Název v anglickém jazyce
The Dependence of the Sensitivity and Reliability of Contactless Conductivity Detection on the Wall Thickness of Electrophoretic Fused-Silica Capillaries
Popis výsledku anglicky
A contactless conductivity detector (C4D) performance has been tested on a simple capillary electrophoretic separation in a standard fused-silica capillary with an external diameter of 360 ?m and in a thin-walled capillary (an external diameter of 150 ?m); the internal diameters of the two capillaries were identical, equal to 75 ?m. Potassium and sodium ions have been separated in a morpholinoethanesulfonic acid/histidine background electrolyte (MES/His), over a wide range of its concentrations (0 - 100mM). At low MES/His concentrations, the C4D response, obtained from the height of the potassium peak, is by 100 to 200 per cent higher for the thin-walled capillary and the calibration dependences are linear, in contrast to the thick-walled capillary. These differences between the two capillaries decrease with increasing MES/His concentration, the C4D response in the thin-walled capillary is then higher by mere 20 per cent and the calibration dependences are linear in both the capillari
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
3-5
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—