Contact less Conductivity Detection in Capillary Electrophoresis Employing Capillaries with Very Low Inner Diameters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F11%3A10104446" target="_blank" >RIV/00216208:11310/11:10104446 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/11:00003217
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201100264" target="_blank" >http://dx.doi.org/10.1002/elan.201100264</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201100264" target="_blank" >10.1002/elan.201100264</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Contact less Conductivity Detection in Capillary Electrophoresis Employing Capillaries with Very Low Inner Diameters
Popis výsledku v původním jazyce
The behaviour of a contactless conductivity detector was studied in its application to capillary electrophoresis employing quartz capillaries with inner diameters (i.d.) of 10 to 75 inn. The detector output signal was measured using KCl as the test electrolyte, within a KCl concentration range from 0 to 100 mmol/L, corresponding to specific conductivities from 0 to 1295 mS/m. When using capillaries with high inner diameters, then the signal-to-noise ratio is high in electrolytes of low conductivity. Onthe other hand, the use of capillaries with low i.d. values is useful in separations employing solutions of high conductivities. The advantages of capillaries with small i.d. values, combined with contactless conductivity detection, are demonstrated on separations of mixtures of inorganic ions and on Separations of neutral mono- and disaccharides.
Název v anglickém jazyce
Contact less Conductivity Detection in Capillary Electrophoresis Employing Capillaries with Very Low Inner Diameters
Popis výsledku anglicky
The behaviour of a contactless conductivity detector was studied in its application to capillary electrophoresis employing quartz capillaries with inner diameters (i.d.) of 10 to 75 inn. The detector output signal was measured using KCl as the test electrolyte, within a KCl concentration range from 0 to 100 mmol/L, corresponding to specific conductivities from 0 to 1295 mS/m. When using capillaries with high inner diameters, then the signal-to-noise ratio is high in electrolytes of low conductivity. Onthe other hand, the use of capillaries with low i.d. values is useful in separations employing solutions of high conductivities. The advantages of capillaries with small i.d. values, combined with contactless conductivity detection, are demonstrated on separations of mixtures of inorganic ions and on Separations of neutral mono- and disaccharides.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F10%2F1231" target="_blank" >GAP206/10/1231: Nové elekroforetické přístupy k monitorování hladin neurotransmiterů bolesti v mozku vyšších živočichů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
1870-1874
Kód UT WoS článku
000294037300015
EID výsledku v databázi Scopus
—