Preparation and properties of reference electrodes based on silver paste amalgam
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F11%3A10105011" target="_blank" >RIV/00216208:11310/11:10105011 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/11:00363716
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201100143" target="_blank" >http://dx.doi.org/10.1002/elan.201100143</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201100143" target="_blank" >10.1002/elan.201100143</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Preparation and properties of reference electrodes based on silver paste amalgam
Popis výsledku v původním jazyce
The preparation and testing of saturated calomel electrodes (SCE-AgPA), mercury-mercurous sulfate (MMSE-AgPA) and mercury-mercuric oxide (MMOE-AgPA) reference electrodes based on silver paste amalgam are described. All three electrodes have shown long-term stability of their potentials (E(SCE-AgPA) = -0.56 + 0.34 mV; E(MMSE-AgPA) = 391.5 +/- 1.4 mV; E(MMOE-AgPA) = -104.9 +/- 0.7 mV vs. classical SCE; test time was 14 months). All paste amalgam electrodes have potentials close to their analogues with metallic mercury. They can therefore replace each other without any recalculation. Peak potentials of anodic dissolution of cadmium measured with the SCE-AgPA and SCE are identical. The greatest resistance to polarization was registered with the SCE-AgPA and significantly lower with other tested electrodes.
Název v anglickém jazyce
Preparation and properties of reference electrodes based on silver paste amalgam
Popis výsledku anglicky
The preparation and testing of saturated calomel electrodes (SCE-AgPA), mercury-mercurous sulfate (MMSE-AgPA) and mercury-mercuric oxide (MMOE-AgPA) reference electrodes based on silver paste amalgam are described. All three electrodes have shown long-term stability of their potentials (E(SCE-AgPA) = -0.56 + 0.34 mV; E(MMSE-AgPA) = 391.5 +/- 1.4 mV; E(MMOE-AgPA) = -104.9 +/- 0.7 mV vs. classical SCE; test time was 14 months). All paste amalgam electrodes have potentials close to their analogues with metallic mercury. They can therefore replace each other without any recalculation. Peak potentials of anodic dissolution of cadmium measured with the SCE-AgPA and SCE are identical. The greatest resistance to polarization was registered with the SCE-AgPA and significantly lower with other tested electrodes.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
2226-2231
Kód UT WoS článku
000295143900032
EID výsledku v databázi Scopus
—