Popis výsledku v původním jazyce
Electrochemical behavior of genotoxic 2-aminofluoren-9-one (2-AFN) was investigated by DC tast polarography (DCTP) and differential pulse polarography (DPP), both at a classical dropping mercury electrode (DME), and by DC voltammetry (DCV), differentialpulse voltammetry (DPV), and adsorptive stripping differential pulse voltammetry (AdSDPV), all at a miniaturized hanging mercury drop minielectrode (HMDmE), in buffered aqueous-methanolic solutions. Optimum conditions were found for the determination of2-AFN by DCTP at DME in the concentration range from 1 x 10-6 to 1 x 10-4 mol l-1 (with a limit of quantification (LQ) of 5 x 10-7 mol l-1), by DPP at DME (from 1 x 10-7 to 1 x 10-4 mol l-1; LQ on level of 1 x 10-7 mol l-1), by DCV and DPV at HMDmE (bothfrom 1 x 10-7 to 1 x 10-4 mol l-1; LQs on level of 2 x 10-7 and 1 x 10-7 mol l-1 for DCV and DPV, respectively), and by AdSDPV at HMDmE (from 2 x 10-9 to 1 x 10-7 mol l-1; LQ ALMOST EQUAL TO 4 x 10-9 mol l-1). Practical applicability of
Název v anglickém jazyce
Polarographic and voltammetric determination of genotoxic 2-aminofluoren-9-one at mercury electrodes
Popis výsledku anglicky
Electrochemical behavior of genotoxic 2-aminofluoren-9-one (2-AFN) was investigated by DC tast polarography (DCTP) and differential pulse polarography (DPP), both at a classical dropping mercury electrode (DME), and by DC voltammetry (DCV), differentialpulse voltammetry (DPV), and adsorptive stripping differential pulse voltammetry (AdSDPV), all at a miniaturized hanging mercury drop minielectrode (HMDmE), in buffered aqueous-methanolic solutions. Optimum conditions were found for the determination of2-AFN by DCTP at DME in the concentration range from 1 x 10-6 to 1 x 10-4 mol l-1 (with a limit of quantification (LQ) of 5 x 10-7 mol l-1), by DPP at DME (from 1 x 10-7 to 1 x 10-4 mol l-1; LQ on level of 1 x 10-7 mol l-1), by DCV and DPV at HMDmE (bothfrom 1 x 10-7 to 1 x 10-4 mol l-1; LQs on level of 2 x 10-7 and 1 x 10-7 mol l-1 for DCV and DPV, respectively), and by AdSDPV at HMDmE (from 2 x 10-9 to 1 x 10-7 mol l-1; LQ ALMOST EQUAL TO 4 x 10-9 mol l-1). Practical applicability of
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Collection of Czechoslovak Chemical Communications
ISSN
0010-0765
e-ISSN
—
Svazek periodika
76
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
13
Strana od-do
1775-1790
Kód UT WoS článku
000299816100023
EID výsledku v databázi Scopus
—