Polarographic and voltammetric determination of genotoxic 4-nitroindane at mercury electrodes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F16%3A10318280" target="_blank" >RIV/00216208:11310/16:10318280 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00706-015-1574-9" target="_blank" >http://dx.doi.org/10.1007/s00706-015-1574-9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-015-1574-9" target="_blank" >10.1007/s00706-015-1574-9</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Polarographic and voltammetric determination of genotoxic 4-nitroindane at mercury electrodes
Popis výsledku v původním jazyce
Determination and electrochemical investigation of genotoxic nitrated polycyclic aromatic hydrocarbon 4-nitroindane (4-NI) were carried out using direct current tast polarography (DCTP) and differential pulse polarography (DPP) at a classical dropping mercury electrode (DME) and using direct current voltammetry (DCV), differential pulse voltammetry (DPV), and cyclic voltammetry (CV) at a hanging mercury drop minielectrode (HMDmE). The following optimal media for the determination of 4-NI were found: methanol-Britton-Robinson (BR) buffer of pH 12.0 (1:1) for DCTP and DPP, methanol-BR buffer of pH 9.0 (1:9) for DCV, and methanol-BR buffer of pH 8.0 (1:9) for DPV. For CV investigation, mixtures of methanol-BR buffer of pH 3.0, 8.0, and 12.0 (1:1) were used. The limits of quantification were: 0.65 A mu mol dm(-3) (DCTP at the DME), 0.10 A mu mol dm(-3) (DPP at the DME), 0.075 A mu mol dm(-3) (DCV at the HMDmE), and 0.070 A mu mol dm(-3) (DPV at the HMDmE). An attempt to increase the determ
Název v anglickém jazyce
Polarographic and voltammetric determination of genotoxic 4-nitroindane at mercury electrodes
Popis výsledku anglicky
Determination and electrochemical investigation of genotoxic nitrated polycyclic aromatic hydrocarbon 4-nitroindane (4-NI) were carried out using direct current tast polarography (DCTP) and differential pulse polarography (DPP) at a classical dropping mercury electrode (DME) and using direct current voltammetry (DCV), differential pulse voltammetry (DPV), and cyclic voltammetry (CV) at a hanging mercury drop minielectrode (HMDmE). The following optimal media for the determination of 4-NI were found: methanol-Britton-Robinson (BR) buffer of pH 12.0 (1:1) for DCTP and DPP, methanol-BR buffer of pH 9.0 (1:9) for DCV, and methanol-BR buffer of pH 8.0 (1:9) for DPV. For CV investigation, mixtures of methanol-BR buffer of pH 3.0, 8.0, and 12.0 (1:1) were used. The limits of quantification were: 0.65 A mu mol dm(-3) (DCTP at the DME), 0.10 A mu mol dm(-3) (DPP at the DME), 0.075 A mu mol dm(-3) (DCV at the HMDmE), and 0.070 A mu mol dm(-3) (DPV at the HMDmE). An attempt to increase the determ
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte für Chemie
ISSN
0026-9247
e-ISSN
—
Svazek periodika
147
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
9
Strana od-do
143-151
Kód UT WoS článku
000367521400019