Voltammetric determination of carcinogenic derivatives of pyrene using a boron-doped diamond film electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F12%3A10126405" target="_blank" >RIV/00216208:11310/12:10126405 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1080/00032719.2011.649455" target="_blank" >http://dx.doi.org/10.1080/00032719.2011.649455</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/00032719.2011.649455" target="_blank" >10.1080/00032719.2011.649455</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric determination of carcinogenic derivatives of pyrene using a boron-doped diamond film electrode
Popis výsledku v původním jazyce
Based on the study of voltammetric behavior of carcinogenic 1-nitropyrene (1-NP), 1-aminopyrene (1-AP), and 1-hydroxypyrene (1-HP), optimum conditions have been found for the determination of these analytes by differential pulse voltammetry (DPV) at a boron-doped diamond film electrode. The optimum medium was methanol-Britton-Robinson buffer (BR buffer) pH 3.0 (70:30) for 1-NP and 1-AP, and methanol-BR buffer pH 5.0 (70: 30) for 1-HP. Concentration dependences of the DPV response were measured in the range 1.10(-6)-1.10(-4) mol dm(-3) (R= -0.9998) with the limit of detection (LOD) 3.10(-7) mol dm(-3) for 1-NP, 1.10(-7)-1.10(-5) mol dm(-3) (R = 0.9971) with LOD 6.10(-8) mol dm(-3) for 1-AP, and 1.10(-7)-1.10(-5) mol dm(-3) (R = 0.9934) with LOD 1.10(-7)mol dm(-3) for 1-HP. Simultaneous determination of 1-NP and 1-AP in a mixture was tested in the methanol-BR buffer pH 3.0 (70: 30) medium as well. The content of 1-AP in the concentration range from 1.10(-6) to 1.10(-4) mol dm(-3) had no
Název v anglickém jazyce
Voltammetric determination of carcinogenic derivatives of pyrene using a boron-doped diamond film electrode
Popis výsledku anglicky
Based on the study of voltammetric behavior of carcinogenic 1-nitropyrene (1-NP), 1-aminopyrene (1-AP), and 1-hydroxypyrene (1-HP), optimum conditions have been found for the determination of these analytes by differential pulse voltammetry (DPV) at a boron-doped diamond film electrode. The optimum medium was methanol-Britton-Robinson buffer (BR buffer) pH 3.0 (70:30) for 1-NP and 1-AP, and methanol-BR buffer pH 5.0 (70: 30) for 1-HP. Concentration dependences of the DPV response were measured in the range 1.10(-6)-1.10(-4) mol dm(-3) (R= -0.9998) with the limit of detection (LOD) 3.10(-7) mol dm(-3) for 1-NP, 1.10(-7)-1.10(-5) mol dm(-3) (R = 0.9971) with LOD 6.10(-8) mol dm(-3) for 1-AP, and 1.10(-7)-1.10(-5) mol dm(-3) (R = 0.9934) with LOD 1.10(-7)mol dm(-3) for 1-HP. Simultaneous determination of 1-NP and 1-AP in a mixture was tested in the methanol-BR buffer pH 3.0 (70: 30) medium as well. The content of 1-AP in the concentration range from 1.10(-6) to 1.10(-4) mol dm(-3) had no
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Letters
ISSN
0003-2719
e-ISSN
—
Svazek periodika
45
Číslo periodika v rámci svazku
5-6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
449-459
Kód UT WoS článku
000302869100003
EID výsledku v databázi Scopus
—