Tubular Detector of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F12%3A10126643" target="_blank" >RIV/00216208:11310/12:10126643 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/12:00385013
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201200443" target="_blank" >http://dx.doi.org/10.1002/elan.201200443</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201200443" target="_blank" >10.1002/elan.201200443</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Tubular Detector of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems
Popis výsledku v původním jazyce
This paper presents the application of the tubular detector based on silver solid amalgam (TD-AgSA) for electrochemical determinations of reducible inorganic (Cd2+, Zn2+) and organic (4-nitrophenol) compounds under flow injection analysis conditions. Thenewly developed TD-AgSA is simple, robust and inexpensive. The limits of detections of Zn2+, Cd2+ and 4-nitrophenol are 1.4x10-6, 7.0x10-7, and 5.0x10-7 mol.dm-3, respectively (i.e. 0.09, 0.08 and 0.07 ppm). The obtained results proved the long-term stability of the detector (RSD of the determination of Zn2+, Cd2+, and 4-nitrophenol were 0.8, 0.9 and 0.8% (n=10; cZn=7.7x10-5 mol.dm-3, cCd=4.5x10-5 mol.dm-3 and c4-NPh=3.6x10-5 mol.dm-3), respectively and its applicability for cathodic measurements in aqueous solutions at potentials up to -2 V.
Název v anglickém jazyce
Tubular Detector of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems
Popis výsledku anglicky
This paper presents the application of the tubular detector based on silver solid amalgam (TD-AgSA) for electrochemical determinations of reducible inorganic (Cd2+, Zn2+) and organic (4-nitrophenol) compounds under flow injection analysis conditions. Thenewly developed TD-AgSA is simple, robust and inexpensive. The limits of detections of Zn2+, Cd2+ and 4-nitrophenol are 1.4x10-6, 7.0x10-7, and 5.0x10-7 mol.dm-3, respectively (i.e. 0.09, 0.08 and 0.07 ppm). The obtained results proved the long-term stability of the detector (RSD of the determination of Zn2+, Cd2+, and 4-nitrophenol were 0.8, 0.9 and 0.8% (n=10; cZn=7.7x10-5 mol.dm-3, cCd=4.5x10-5 mol.dm-3 and c4-NPh=3.6x10-5 mol.dm-3), respectively and its applicability for cathodic measurements in aqueous solutions at potentials up to -2 V.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F11%2F1638" target="_blank" >GAP206/11/1638: Nové elektrochemické senzory a detekční techniky pro analýzu struktury a interakcí nukleových kyselin</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
2230-2234
Kód UT WoS článku
000311910800003
EID výsledku v databázi Scopus
—