Construction and Application of Tubular Detector and Porous Flow-through Detector/Reactor of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F13%3A10172708" target="_blank" >RIV/00216208:11310/13:10172708 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/13:00392968
Výsledek na webu
<a href="http://www.bestservis.eu/upload/file/Sbornik_2013.pdf" target="_blank" >http://www.bestservis.eu/upload/file/Sbornik_2013.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Construction and Application of Tubular Detector and Porous Flow-through Detector/Reactor of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems
Popis výsledku v původním jazyce
This paper presents the preparation and application of two new arrangements of silver solid amalgam (AgSA) electrodes for measurements in flow systems - tubular detector based on compact AgSA, and flow-through detector (or reactor) prepared from porous AgSA. Both electrodes were tested for electrochemical determinations of reducible inorganic (Cd2+, Zn2+) and organic (4-nitrophenol, lomustine) compounds under FIA with amperometric detection (Cd2+, Zn2+, 4-nitrophenol) and flow-DPV (lomustine). Furthermore, by combination of the porous reactor with immobilized enzyme and tubular detector the flow amperometric enzymatic biosensor was constructed for determination of glucose in a sample of honey and cholesterol and sarcosine in model samples.
Název v anglickém jazyce
Construction and Application of Tubular Detector and Porous Flow-through Detector/Reactor of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems
Popis výsledku anglicky
This paper presents the preparation and application of two new arrangements of silver solid amalgam (AgSA) electrodes for measurements in flow systems - tubular detector based on compact AgSA, and flow-through detector (or reactor) prepared from porous AgSA. Both electrodes were tested for electrochemical determinations of reducible inorganic (Cd2+, Zn2+) and organic (4-nitrophenol, lomustine) compounds under FIA with amperometric detection (Cd2+, Zn2+, 4-nitrophenol) and flow-DPV (lomustine). Furthermore, by combination of the porous reactor with immobilized enzyme and tubular detector the flow amperometric enzymatic biosensor was constructed for determination of glucose in a sample of honey and cholesterol and sarcosine in model samples.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník přednášek mezinárodní odborné konference XXXIII. Moderní Elektrochemické Metody Jetřichovice 20. - 24. května 2013
ISBN
978-80-905221-1-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
84-87
Název nakladatele
Srsenová Lenka - BEST servis Ústí nad Labem
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice, Czech Republic
Datum konání akce
20. 5. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—