Electrochemical Biosensors Based on Enzymatic Reactor of Silver Solid Amalgam Powder for Measurements in Flow Systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F14%3A10282023" target="_blank" >RIV/00216208:11310/14:10282023 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/14:00430320
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201400224" target="_blank" >http://dx.doi.org/10.1002/elan.201400224</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201400224" target="_blank" >10.1002/elan.201400224</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical Biosensors Based on Enzymatic Reactor of Silver Solid Amalgam Powder for Measurements in Flow Systems
Popis výsledku v původním jazyce
An enzymatic reactor based on silver solid amalgam powder was suggested as the main part of bio-sensors in flow systems for the first time. Biosensors were tested with following enzymes: ascorbate oxidase, glucose oxidase, catalase, tyrosinase and laccase. The current response of each biosensor was optimized with respect to the detection potential, flow rate, the injection and reactor volume. Relative standard deviation for detection with the studied enzymes was found to be in the range of 0.81-2.1%. The biosensor with the ascorbate oxidase reactor was used for determination of ascorbic acid in the vitamin tablets Celaskon.
Název v anglickém jazyce
Electrochemical Biosensors Based on Enzymatic Reactor of Silver Solid Amalgam Powder for Measurements in Flow Systems
Popis výsledku anglicky
An enzymatic reactor based on silver solid amalgam powder was suggested as the main part of bio-sensors in flow systems for the first time. Biosensors were tested with following enzymes: ascorbate oxidase, glucose oxidase, catalase, tyrosinase and laccase. The current response of each biosensor was optimized with respect to the detection potential, flow rate, the injection and reactor volume. Relative standard deviation for detection with the studied enzymes was found to be in the range of 0.81-2.1%. The biosensor with the ascorbate oxidase reactor was used for determination of ascorbic acid in the vitamin tablets Celaskon.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F11%2F1638" target="_blank" >GAP206/11/1638: Nové elektrochemické senzory a detekční techniky pro analýzu struktury a interakcí nukleových kyselin</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
1729-1738
Kód UT WoS článku
000340557700012
EID výsledku v databázi Scopus
—