Voltammetric Determination of Insecticide Thiamethoxam on Silver Solid Amalgam Electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F14%3A10282027" target="_blank" >RIV/00216208:11310/14:10282027 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.electacta.2014.01.081" target="_blank" >http://dx.doi.org/10.1016/j.electacta.2014.01.081</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.electacta.2014.01.081" target="_blank" >10.1016/j.electacta.2014.01.081</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Determination of Insecticide Thiamethoxam on Silver Solid Amalgam Electrode
Popis výsledku v původním jazyce
This work demonstrates the applicability of differential pulse voltammetry (DPV) for the determination of the insecticide thiamethoxam at a non-toxic mercury meniscus modified silver solid amalgam electrode (m-AgSAE). The optimum supporting electrolyte was found to be Britton-Robinson (BR) buffer, pH 10. The target compound was quantified directly in spiked drinking and river water samples in the range from 100 mu mol L-1 to limits of determination (LOQs) 0.36 and 0.46 mu mol L-1, respectively. After preliminary separation and preconcentration by solid phase extraction (SPE) using Lichrolut EN cartridges, quantification in spiked river and drinking water samples was possible in the range from 100 nmol L-1 to LOQs 1.3 and 1.1 nmol L-1, respectively. m-AgSAE is practically non-toxic, possesses good mechanical stability and is easy to handle and activate and thus represents a suitable alternative to the hanging mercury drop electrode (HMDE).
Název v anglickém jazyce
Voltammetric Determination of Insecticide Thiamethoxam on Silver Solid Amalgam Electrode
Popis výsledku anglicky
This work demonstrates the applicability of differential pulse voltammetry (DPV) for the determination of the insecticide thiamethoxam at a non-toxic mercury meniscus modified silver solid amalgam electrode (m-AgSAE). The optimum supporting electrolyte was found to be Britton-Robinson (BR) buffer, pH 10. The target compound was quantified directly in spiked drinking and river water samples in the range from 100 mu mol L-1 to limits of determination (LOQs) 0.36 and 0.46 mu mol L-1, respectively. After preliminary separation and preconcentration by solid phase extraction (SPE) using Lichrolut EN cartridges, quantification in spiked river and drinking water samples was possible in the range from 100 nmol L-1 to LOQs 1.3 and 1.1 nmol L-1, respectively. m-AgSAE is practically non-toxic, possesses good mechanical stability and is easy to handle and activate and thus represents a suitable alternative to the hanging mercury drop electrode (HMDE).
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrochimica Acta
ISSN
0013-4686
e-ISSN
—
Svazek periodika
140
Číslo periodika v rámci svazku
September
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
5-10
Kód UT WoS článku
000342528600002
EID výsledku v databázi Scopus
—