Use of the Silver Solid Amalgam Electrode for Determination of 5-Nitroindazole
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F14%3A10285806" target="_blank" >RIV/00216208:11310/14:10285806 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/14:00428763
Výsledek na webu
<a href="http://www.bestservis.eu/upload/file/Sbornik_metody14.pdf" target="_blank" >http://www.bestservis.eu/upload/file/Sbornik_metody14.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Use of the Silver Solid Amalgam Electrode for Determination of 5-Nitroindazole
Popis výsledku v původním jazyce
The voltammetric behavior of 5- nitroindazole (5-NI) has been investigated using mercury meniscus modified (m-AgSAE) silver solid amalgam electrode (inner diameter 0.5 mm). Differential pulse voltammetry (DPV) and cyclic voltammetry (CV) were used for study of electrochemical behavior of 5-NI. Britton-Robinson buffer was found to be the best available supporting electrolyte for 5-NI determination. The reaction mechanism was investigated by CV and by elimination voltammetry with linear scan (EVLS). DPV with optimized working parameters was applied for analysis of model solutions containing 5-NI. The limit of detection was calculated as 0.14 uM L for m-AgSAE. Proposed method was successfully tested for analysis of real water samples spiked by 5-NI.
Název v anglickém jazyce
Use of the Silver Solid Amalgam Electrode for Determination of 5-Nitroindazole
Popis výsledku anglicky
The voltammetric behavior of 5- nitroindazole (5-NI) has been investigated using mercury meniscus modified (m-AgSAE) silver solid amalgam electrode (inner diameter 0.5 mm). Differential pulse voltammetry (DPV) and cyclic voltammetry (CV) were used for study of electrochemical behavior of 5-NI. Britton-Robinson buffer was found to be the best available supporting electrolyte for 5-NI determination. The reaction mechanism was investigated by CV and by elimination voltammetry with linear scan (EVLS). DPV with optimized working parameters was applied for analysis of model solutions containing 5-NI. The limit of detection was calculated as 0.14 uM L for m-AgSAE. Proposed method was successfully tested for analysis of real water samples spiked by 5-NI.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP208%2F12%2F1645" target="_blank" >GAP208/12/1645: Aspekty transportu rizikových kovů přes biologické membrány</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník přednášek mezinárodní odborné konference XXXIV. Moderní Elektrochemické Metody Jetřichovice 19.- 23. května 2014
ISBN
978-80-905221-2-1
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
109-113
Název nakladatele
Srsenová Lenka - Best servis Ústí nad Labem
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice, Czech Republic
Datum konání akce
19. 5. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—