Voltammetric Determination of Nitrofurantoin at a Mercury Meniscus Modified Silver Solid Amalgam Electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10291006" target="_blank" >RIV/00216208:11310/15:10291006 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201400410" target="_blank" >http://dx.doi.org/10.1002/elan.201400410</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201400410" target="_blank" >10.1002/elan.201400410</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Determination of Nitrofurantoin at a Mercury Meniscus Modified Silver Solid Amalgam Electrode
Popis výsledku v původním jazyce
Electrochemical behavior of nitrofurantoin (NF) was studied by direct current voltammetry (DCV), differential pulse voltammetry (DPV), and cyclic voltammetry (CV) using a mercury meniscus modified silver solid amalgam electrode (m-AgSAE). Voltammetric behavior of NF was studied in cathodic region of potentials in dependence on pH. pH 7.0 was selected as an optimal medium for the determination of NF by both DCV and DPV, with the optimal methanol-water volume ratio of 1 : 9. In order to reduce the negative influence of electrode passivation, the suitable regeneration potentials were found (0 mV and -900 mV). The optimal conditions were found for the determination of NF in concentration ranges from 6 x 10(-6) mol L-1 to 1 x 10(-4) mol L-1 using DCV technique, and from 2 x 10(-7) mol L-1 to 1 x 10(-4) mol L-1 using DPV technique, both in the medium of methanol-Britton-Robinson buffer pH 7.0 (1 : 9). The attained limit of quantification (LOQ) of NF was 1.6 x 10(-6) mol L-1 for DCV and 8.1 x
Název v anglickém jazyce
Voltammetric Determination of Nitrofurantoin at a Mercury Meniscus Modified Silver Solid Amalgam Electrode
Popis výsledku anglicky
Electrochemical behavior of nitrofurantoin (NF) was studied by direct current voltammetry (DCV), differential pulse voltammetry (DPV), and cyclic voltammetry (CV) using a mercury meniscus modified silver solid amalgam electrode (m-AgSAE). Voltammetric behavior of NF was studied in cathodic region of potentials in dependence on pH. pH 7.0 was selected as an optimal medium for the determination of NF by both DCV and DPV, with the optimal methanol-water volume ratio of 1 : 9. In order to reduce the negative influence of electrode passivation, the suitable regeneration potentials were found (0 mV and -900 mV). The optimal conditions were found for the determination of NF in concentration ranges from 6 x 10(-6) mol L-1 to 1 x 10(-4) mol L-1 using DCV technique, and from 2 x 10(-7) mol L-1 to 1 x 10(-4) mol L-1 using DPV technique, both in the medium of methanol-Britton-Robinson buffer pH 7.0 (1 : 9). The attained limit of quantification (LOQ) of NF was 1.6 x 10(-6) mol L-1 for DCV and 8.1 x
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
185-192
Kód UT WoS článku
000347838300022
EID výsledku v databázi Scopus
2-s2.0-84920944860