The analysis of linear and monomethylalkanes in exhaled breath samples by GC x GC-FID and GC-MS/MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10292477" target="_blank" >RIV/00216208:11310/15:10292477 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064165:_____/15:10292477
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jchromb.2014.11.026" target="_blank" >http://dx.doi.org/10.1016/j.jchromb.2014.11.026</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jchromb.2014.11.026" target="_blank" >10.1016/j.jchromb.2014.11.026</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The analysis of linear and monomethylalkanes in exhaled breath samples by GC x GC-FID and GC-MS/MS
Popis výsledku v původním jazyce
A new arrangement of the INCAT (inside needle capillary adsorption trap) device with Carbopack X and Carboxen 1000 as sorbent materials was applied for sampling, preconcentration and injection of C-6-C-19 n-alkanes and their monomethyl analogs in exhaledbreath samples. For the analysis both GC MS/MS and GC x GC-FID techniques were used. Identification of the analytes was based on standards, measured retention indices and selective SRM transitions of the individual isomers. The GC-MS/MS detection limitswere in the range from 2.1 pg for n-tetradecane to 86 pg for 5-methyloctadecane. The GC x GC-FID detection limits ranged from 19 pg for n-dodecane to 110 pg for 3-methyloctane.
Název v anglickém jazyce
The analysis of linear and monomethylalkanes in exhaled breath samples by GC x GC-FID and GC-MS/MS
Popis výsledku anglicky
A new arrangement of the INCAT (inside needle capillary adsorption trap) device with Carbopack X and Carboxen 1000 as sorbent materials was applied for sampling, preconcentration and injection of C-6-C-19 n-alkanes and their monomethyl analogs in exhaledbreath samples. For the analysis both GC MS/MS and GC x GC-FID techniques were used. Identification of the analytes was based on standards, measured retention indices and selective SRM transitions of the individual isomers. The GC-MS/MS detection limitswere in the range from 2.1 pg for n-tetradecane to 86 pg for 5-methyloctadecane. The GC x GC-FID detection limits ranged from 19 pg for n-dodecane to 110 pg for 3-methyloctane.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
ISSN
1570-0232
e-ISSN
—
Svazek periodika
978
Číslo periodika v rámci svazku
January
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
62-69
Kód UT WoS článku
000348336100008
EID výsledku v databázi Scopus
2-s2.0-84919782609