Lead Isotopic Composition in Biogenic Certified Reference Materials Determined by Different ICP-based Mass Spectrometric Techniques
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10313127" target="_blank" >RIV/00216208:11310/15:10313127 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985831:_____/15:00443043 RIV/61389005:_____/15:00443427
Výsledek na webu
<a href="http://dx.doi.org/10.1111/j.1751-908X.2014.00280.x" target="_blank" >http://dx.doi.org/10.1111/j.1751-908X.2014.00280.x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/j.1751-908X.2014.00280.x" target="_blank" >10.1111/j.1751-908X.2014.00280.x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lead Isotopic Composition in Biogenic Certified Reference Materials Determined by Different ICP-based Mass Spectrometric Techniques
Popis výsledku v původním jazyce
This work presents data for the radiogenic Pb isotopic ratios (206Pb/207Pb and 208Pb/206Pb) in nine biogenic certified reference materials (NIST SRM 1515, 1566b, 1570a, 1573a, 1575a; BCR 100, BCR 101, BCR 670 and IAEA 359), which are suitable for analytical quality control in environmental research. The results were obtained using three different types of ICP-based mass spectrometer (quadrupole-based/magnetic sector field single-collector ICP-MS instruments and a multi-collector ICP-MS) and applying different mass bias correction procedures (calibrator-sample bracketing and external Tl normalisation) with and without Pb separation from the matrix using ion exchange chromatography. In the majority of the samples, the measurements from all three of the ICP-MS instruments were in agreement within +- 0.1%, despite the lower analytical precision of the single-collector ICP-MS instruments. We demonstrate that the presence of the sample matrix did not significantly influence the Pb isotopic r
Název v anglickém jazyce
Lead Isotopic Composition in Biogenic Certified Reference Materials Determined by Different ICP-based Mass Spectrometric Techniques
Popis výsledku anglicky
This work presents data for the radiogenic Pb isotopic ratios (206Pb/207Pb and 208Pb/206Pb) in nine biogenic certified reference materials (NIST SRM 1515, 1566b, 1570a, 1573a, 1575a; BCR 100, BCR 101, BCR 670 and IAEA 359), which are suitable for analytical quality control in environmental research. The results were obtained using three different types of ICP-based mass spectrometer (quadrupole-based/magnetic sector field single-collector ICP-MS instruments and a multi-collector ICP-MS) and applying different mass bias correction procedures (calibrator-sample bracketing and external Tl normalisation) with and without Pb separation from the matrix using ion exchange chromatography. In the majority of the samples, the measurements from all three of the ICP-MS instruments were in agreement within +- 0.1%, despite the lower analytical precision of the single-collector ICP-MS instruments. We demonstrate that the presence of the sample matrix did not significantly influence the Pb isotopic r
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP504%2F11%2F0484" target="_blank" >GAP504/11/0484: Hyperakumulace těžkých kovů velkými houbami – molekulární, geomykologické a ekotaxonomické aspekty</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Geostandards and Geoanalytical Research
ISSN
1639-4488
e-ISSN
—
Svazek periodika
39
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
209-220
Kód UT WoS článku
000352026200005
EID výsledku v databázi Scopus
2-s2.0-84925869762