Popis výsledku v původním jazyce
2,4,6-Trinitrophenol (picric acid, PA) is known to have severe genotoxic effects, while adverse reactions are observed in humans as well. World Health Organization (WHO) has designated PA as one of the priority contaminants of the surface waters. In thiscontribution, a bismuth bulk electrode was used for investigation of the electrochemical behavior of PA, using differential pulse voltammetry, and a new method for its determination was subsequently developed. The optimal medium for the determination was 0.1 mol L-1 acetate buffer pH 4.0. The calibration curves were measured in the concentration range from 2 to 100 mu mol L-1, with the limits of quantification 0.7 mu mol L-1 in deionized water, 1.1 mu mol L-1 in drinking water, and 1.8 mu mol L-1 in river water. The RSD (n = 20) were 3.2, 6.2, and 9.9 %, respectively.
Název v anglickém jazyce
Voltammetric Determination of Environmental Pollutant 2,4,6-Trinitrophenol Using a Bismuth Bulk Electrode
Popis výsledku anglicky
2,4,6-Trinitrophenol (picric acid, PA) is known to have severe genotoxic effects, while adverse reactions are observed in humans as well. World Health Organization (WHO) has designated PA as one of the priority contaminants of the surface waters. In thiscontribution, a bismuth bulk electrode was used for investigation of the electrochemical behavior of PA, using differential pulse voltammetry, and a new method for its determination was subsequently developed. The optimal medium for the determination was 0.1 mol L-1 acetate buffer pH 4.0. The calibration curves were measured in the concentration range from 2 to 100 mu mol L-1, with the limits of quantification 0.7 mu mol L-1 in deionized water, 1.1 mu mol L-1 in drinking water, and 1.8 mu mol L-1 in river water. The RSD (n = 20) were 3.2, 6.2, and 9.9 %, respectively.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník přednášek mezinárodní odborné konference XXXV. Moderní elektrochemické metody
ISBN
978-80-905221-3-8
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
185-189
Název nakladatele
Srsenová Lenka - Best servis Ústí nad Labem
Místo vydání
Ústí nad Labem, Czech Republic
Místo konání akce
Jetřichovice, Czech Republic
Datum konání akce
18. 5. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000358792900042