Anodic voltammetric determination of 2-nitrophenol at a carbon film electrode in model samples of drinking water
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10328314" target="_blank" >RIV/00216208:11310/15:10328314 - isvavai.cz</a>
Výsledek na webu
<a href="https://web.natur.cuni.cz/analchem/isc-mac/" target="_blank" >https://web.natur.cuni.cz/analchem/isc-mac/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Anodic voltammetric determination of 2-nitrophenol at a carbon film electrode in model samples of drinking water
Popis výsledku v původním jazyce
This work is focused on the development of new differential pulse voltammetric (DPV) method for the determination of submicromolar concentrations of 2-nitrophenol using carbon film electrode. The highest and the best developed DPV peak was obtained using Britton-Robinson buffer of pH = 6.0. The best repeatability was obtained by inserting regeneration potentials E-in = 1300 mV; E-fin = 0 mV. The calibration curves of 2-nitrophenol in both deionized and drinking water were linear in the concentration range from 4x10(-7) to 1x10(-4) mol L. Limit of quantification for DPV in deionized water was 2.0x10(-7) mol L-1 and in drinking water 1.0x10(-7) mol L-1.
Název v anglickém jazyce
Anodic voltammetric determination of 2-nitrophenol at a carbon film electrode in model samples of drinking water
Popis výsledku anglicky
This work is focused on the development of new differential pulse voltammetric (DPV) method for the determination of submicromolar concentrations of 2-nitrophenol using carbon film electrode. The highest and the best developed DPV peak was obtained using Britton-Robinson buffer of pH = 6.0. The best repeatability was obtained by inserting regeneration potentials E-in = 1300 mV; E-fin = 0 mV. The calibration curves of 2-nitrophenol in both deionized and drinking water were linear in the concentration range from 4x10(-7) to 1x10(-4) mol L. Limit of quantification for DPV in deionized water was 2.0x10(-7) mol L-1 and in drinking water 1.0x10(-7) mol L-1.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PROCEEDINGS OF THE 11TH INTERNATIONAL STUDENTS CONFERENCE "MODERN ANALYTICAL CHEMISTRY"
ISBN
978-80-7444-036-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
166-169
Název nakladatele
CHARLES UNIV, FAC SCIENCE
Místo vydání
PRAGUE 2
Místo konání akce
Prague
Datum konání akce
22. 9. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000383853900029