Electrochemical Study of 5-Nitroquinoline Using Carbon Film Electrode for its Voltammetric Determination in Model Samples of Drinking and River Water
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10321596" target="_blank" >RIV/00216208:11310/15:10321596 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.bestservis.eu/upload/file/Sbornik_metody15.pdf" target="_blank" >http://www.bestservis.eu/upload/file/Sbornik_metody15.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical Study of 5-Nitroquinoline Using Carbon Film Electrode for its Voltammetric Determination in Model Samples of Drinking and River Water
Popis výsledku v původním jazyce
This work is focused on searching for optimized working conditions for determination of 5-nitroquinoline (5-NQ) using modern voltammetric methods. The following optimal conditions were found: Britton-Robinson (BR) buffer of pH 11.0 for both methods (DCVand DPV), the regeneration potential cycles (E-in = 0 mV, E-fin = 0 mV). Under these conditions limits of quantification (LOQ) were found to be 1.0x10(-6) mol L-1 for DCV and 4.0x10(-7) mol L-1 for DPV in deionized water. The LOQ for model samples of water were 2.0x10(-7) mol L-1 for drinking water and 6.0x10-7 mol L-1 for river water, both using DPV.
Název v anglickém jazyce
Electrochemical Study of 5-Nitroquinoline Using Carbon Film Electrode for its Voltammetric Determination in Model Samples of Drinking and River Water
Popis výsledku anglicky
This work is focused on searching for optimized working conditions for determination of 5-nitroquinoline (5-NQ) using modern voltammetric methods. The following optimal conditions were found: Britton-Robinson (BR) buffer of pH 11.0 for both methods (DCVand DPV), the regeneration potential cycles (E-in = 0 mV, E-fin = 0 mV). Under these conditions limits of quantification (LOQ) were found to be 1.0x10(-6) mol L-1 for DCV and 4.0x10(-7) mol L-1 for DPV in deionized water. The LOQ for model samples of water were 2.0x10(-7) mol L-1 for drinking water and 6.0x10-7 mol L-1 for river water, both using DPV.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník přednášek mezinárodní odborné konference XXXV. Moderní elektrochemické metody
ISBN
978-80-905221-3-8
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
194-198
Název nakladatele
Srsenová Lenka - Best servis Ústí nad Labem
Místo vydání
Ústí nad Labem, Czech Republic
Místo konání akce
Jetřichovice, Czech Republic
Datum konání akce
18. 5. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000358792900044