Oxidative and Reductive Detection Modes for Determination of Nitrophenols by High-performance Liquid Chromatography with Amperometric Detection at a Boron Doped Diamond Electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F16%3A10312332" target="_blank" >RIV/00216208:11310/16:10312332 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1080/00032719.2014.1003424" target="_blank" >http://dx.doi.org/10.1080/00032719.2014.1003424</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/00032719.2014.1003424" target="_blank" >10.1080/00032719.2014.1003424</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Oxidative and Reductive Detection Modes for Determination of Nitrophenols by High-performance Liquid Chromatography with Amperometric Detection at a Boron Doped Diamond Electrode
Popis výsledku v původním jazyce
High performance liquid chromatography with electrochemical detection using a wall-jet arrangement with a working boron-doped diamond film electrode was used for the determination of 2-nitrophenol, 4-nitrophenol, and 2,4-dinitrophenol using reduction andoxidation modes. The optimal conditions for separation at a C18 reverse phase column (125x4 millimeters, 5 micrometers) and amperometric detection of these nitrophenols were determined. Acetate buffer (0.05mole per liter pH 4.7/methanol 58/42, v/v) waschosen as the mobile phase for cathodic detection at the potential of -1.2 volts. The linear dynamic range was 2x10(-6) to 1x10(-4)mole per liter and the limits of detection were from 0.7 to 1.2 micromole per liter. For anodic detection, the mobile phasewas 0.05mole per liter phosphate buffer pH 6.75/methanol (65/35, v/v) at a detection potential of +1.3 volts. The linear dynamic range was from 2x10(-6) to 1x10(-4)mole per liter with limits of detection from 0.6 to 1.5 micromoles per li
Název v anglickém jazyce
Oxidative and Reductive Detection Modes for Determination of Nitrophenols by High-performance Liquid Chromatography with Amperometric Detection at a Boron Doped Diamond Electrode
Popis výsledku anglicky
High performance liquid chromatography with electrochemical detection using a wall-jet arrangement with a working boron-doped diamond film electrode was used for the determination of 2-nitrophenol, 4-nitrophenol, and 2,4-dinitrophenol using reduction andoxidation modes. The optimal conditions for separation at a C18 reverse phase column (125x4 millimeters, 5 micrometers) and amperometric detection of these nitrophenols were determined. Acetate buffer (0.05mole per liter pH 4.7/methanol 58/42, v/v) waschosen as the mobile phase for cathodic detection at the potential of -1.2 volts. The linear dynamic range was 2x10(-6) to 1x10(-4)mole per liter and the limits of detection were from 0.7 to 1.2 micromole per liter. For anodic detection, the mobile phasewas 0.05mole per liter phosphate buffer pH 6.75/methanol (65/35, v/v) at a detection potential of +1.3 volts. The linear dynamic range was from 2x10(-6) to 1x10(-4)mole per liter with limits of detection from 0.6 to 1.5 micromoles per li
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Letters
ISSN
0003-2719
e-ISSN
—
Svazek periodika
49
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
66-79
Kód UT WoS článku
000363048900007