Determination of benzocaine using HPLC and FIA with amperometric detection on a carbon paste electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F11%3A10104905" target="_blank" >RIV/00216208:11310/11:10104905 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201000646" target="_blank" >http://dx.doi.org/10.1002/elan.201000646</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201000646" target="_blank" >10.1002/elan.201000646</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of benzocaine using HPLC and FIA with amperometric detection on a carbon paste electrode
Popis výsledku v původním jazyce
A new method for benzocaine determination employing FIA and HPLC with electrochemical detection on a carbon paste electrode was developed. The optimum conditions for the determination were found. Carrier solution for FIA consisted of B-R buffer pH 4 (80%methanol, v/v) and used flow rate was 1.0 mLmin(-1). Mobile phase for HPLC consisted of B-R buffer pH 4 (75% methanol, v/v) with flow rate 0.4 mLmin(-1). Working potential of +1.2 V was employed. Practical applicability of the methods was tested on thedetermination of benzocaine in selected pharmaceuticals. The results were in agreement with results obtained using spectrophotometric detection and with one exception also with the content declared by the manufacturer.
Název v anglickém jazyce
Determination of benzocaine using HPLC and FIA with amperometric detection on a carbon paste electrode
Popis výsledku anglicky
A new method for benzocaine determination employing FIA and HPLC with electrochemical detection on a carbon paste electrode was developed. The optimum conditions for the determination were found. Carrier solution for FIA consisted of B-R buffer pH 4 (80%methanol, v/v) and used flow rate was 1.0 mLmin(-1). Mobile phase for HPLC consisted of B-R buffer pH 4 (75% methanol, v/v) with flow rate 0.4 mLmin(-1). Working potential of +1.2 V was employed. Practical applicability of the methods was tested on thedetermination of benzocaine in selected pharmaceuticals. The results were in agreement with results obtained using spectrophotometric detection and with one exception also with the content declared by the manufacturer.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06035" target="_blank" >LC06035: Centrum biofyzikální chemie, bioelektrochemie a bioanalýzy. Nové nástroje pro genomiku, proteomiku a biomedicínu.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
662-666
Kód UT WoS článku
000288093400014
EID výsledku v databázi Scopus
—