Determination of Trans-Resveratrol Using Voltammetric and Amperometric methods at Carbon Fiber Rod Electrode and Carbon Paste Electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F12%3A10129293" target="_blank" >RIV/00216208:11310/12:10129293 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.electrochemsci.org/papers/vol7/71009221.pdf" target="_blank" >http://www.electrochemsci.org/papers/vol7/71009221.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Trans-Resveratrol Using Voltammetric and Amperometric methods at Carbon Fiber Rod Electrode and Carbon Paste Electrode
Popis výsledku v původním jazyce
A new method for the determination of trans-resveratrol employing voltammetry (direct current voltammetry (DCV), differential pulse voltammetry (DPV), adsorptive stripping differential pulse voltammetry (AdSDPV)) and flow injection analysis (FIA) with electrochemical detection (ED) at a carbon fiber rod electrode (CFRE) was developed and compared with the voltammetric determination using carbon paste electrode (CPE) and FIA with spectrophotometric detection (SPD). Optimum conditions were found to be Britton-Robinson (BR) buffer pH 2 - methanol (1:1, v/v) for voltammetry (except for AdSDPV where BR buffer pH 10 - methanol mixture, 95:5, v/v was used), and BR buffer pH 10 - methanol (1:1, v/v) medium with the detection potential + 1.0 V or wavelength 306nm for FIA. Practical applicability of the methods was tested on the determination of trans-resveratrol in Evelor pastilles. The results were in agreement with the results obtained using CPE and spectrophotometric detection and also with
Název v anglickém jazyce
Determination of Trans-Resveratrol Using Voltammetric and Amperometric methods at Carbon Fiber Rod Electrode and Carbon Paste Electrode
Popis výsledku anglicky
A new method for the determination of trans-resveratrol employing voltammetry (direct current voltammetry (DCV), differential pulse voltammetry (DPV), adsorptive stripping differential pulse voltammetry (AdSDPV)) and flow injection analysis (FIA) with electrochemical detection (ED) at a carbon fiber rod electrode (CFRE) was developed and compared with the voltammetric determination using carbon paste electrode (CPE) and FIA with spectrophotometric detection (SPD). Optimum conditions were found to be Britton-Robinson (BR) buffer pH 2 - methanol (1:1, v/v) for voltammetry (except for AdSDPV where BR buffer pH 10 - methanol mixture, 95:5, v/v was used), and BR buffer pH 10 - methanol (1:1, v/v) medium with the detection potential + 1.0 V or wavelength 306nm for FIA. Practical applicability of the methods was tested on the determination of trans-resveratrol in Evelor pastilles. The results were in agreement with the results obtained using CPE and spectrophotometric detection and also with
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrochemical Science
ISSN
1452-3981
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
RS - Srbská republika
Počet stran výsledku
11
Strana od-do
9221-9231
Kód UT WoS článku
000312933600015
EID výsledku v databázi Scopus
—