Determination of bromhexine at a glassy carbon paste electrode using differential pulse voltammetry and flow injection analysis with amperometric detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F15%3A10312012" target="_blank" >RIV/00216208:11310/15:10312012 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00706-015-1469-9" target="_blank" >http://dx.doi.org/10.1007/s00706-015-1469-9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-015-1469-9" target="_blank" >10.1007/s00706-015-1469-9</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of bromhexine at a glassy carbon paste electrode using differential pulse voltammetry and flow injection analysis with amperometric detection
Popis výsledku v původním jazyce
New electrochemical methods for the determination of bromhexine based on differential pulse voltammetry (DPV) and flow injection analysis with amperometric detection (FIA-ED) were developed using a glassy carbon paste electrode. Optimal supporting electrolyte for DPV measurement was methanol/Britton-Robinson buffer pH 9 (80:20, v/v). In the case of FIA-ED, optimal conditions were as follows: detection potential +1.1 V, flow rate 1.0 cm(3) min(-1), injected volume 0.1 cm(3), and carrier solution methanol-ten times diluted B-R buffer of pH 9 (80:20, v/v). Detection limit was 2.0 x 10(-6) mol dm(-3) for DPV and 3.1 x 10(-7) mol dm(-3) for FIA-ED. The applicability of the newly developed methods was verified by the determination of bromhexine in pharmaceutical preparations (tablets of Bromhexin-EGIS and Bromhexin 8 BC).
Název v anglickém jazyce
Determination of bromhexine at a glassy carbon paste electrode using differential pulse voltammetry and flow injection analysis with amperometric detection
Popis výsledku anglicky
New electrochemical methods for the determination of bromhexine based on differential pulse voltammetry (DPV) and flow injection analysis with amperometric detection (FIA-ED) were developed using a glassy carbon paste electrode. Optimal supporting electrolyte for DPV measurement was methanol/Britton-Robinson buffer pH 9 (80:20, v/v). In the case of FIA-ED, optimal conditions were as follows: detection potential +1.1 V, flow rate 1.0 cm(3) min(-1), injected volume 0.1 cm(3), and carrier solution methanol-ten times diluted B-R buffer of pH 9 (80:20, v/v). Detection limit was 2.0 x 10(-6) mol dm(-3) for DPV and 3.1 x 10(-7) mol dm(-3) for FIA-ED. The applicability of the newly developed methods was verified by the determination of bromhexine in pharmaceutical preparations (tablets of Bromhexin-EGIS and Bromhexin 8 BC).
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte für Chemie
ISSN
0026-9247
e-ISSN
—
Svazek periodika
146
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
5
Strana od-do
1211-1215
Kód UT WoS článku
000358163800003
EID výsledku v databázi Scopus
2-s2.0-84927555965