Application of silver solid amalgam electrode for determination of formamidine amitraz
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F16%3A10318284" target="_blank" >RIV/00216208:11310/16:10318284 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/16:00453783
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00706-015-1575-8" target="_blank" >http://dx.doi.org/10.1007/s00706-015-1575-8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00706-015-1575-8" target="_blank" >10.1007/s00706-015-1575-8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of silver solid amalgam electrode for determination of formamidine amitraz
Popis výsledku v původním jazyce
The voltammetric behavior of pesticide amitraz was investigated at polished silver solid amalgam electrode (p-AgSAE) and at mercury meniscus modified silver solid amalgam electrode (m-AgSAE) (inner diameter 0.5 mm). The results were compared with those obtained using hanging mercury drop electrode. The reaction mechanism was studied by direct current voltammetry and elimination voltammetry with linear scan. Optimum conditions for determination using differential pulse adsorption stripping voltammetry ofthis compound were found in Britton-Robinson buffer mixed with ethanol (4:1 v/v). The limits of detection were calculated as 8.9 x 10(-9) mol dm(-3) (with t (acc) = 20 s) for m-AgSAE and as 0.168 x 10(-6) mol dm(-3) (with t (acc) = 20 s) for p-AgSAE. The proposed method was successfully applied for determination of amitraz in real samples of river water. [GRAPHICS] .
Název v anglickém jazyce
Application of silver solid amalgam electrode for determination of formamidine amitraz
Popis výsledku anglicky
The voltammetric behavior of pesticide amitraz was investigated at polished silver solid amalgam electrode (p-AgSAE) and at mercury meniscus modified silver solid amalgam electrode (m-AgSAE) (inner diameter 0.5 mm). The results were compared with those obtained using hanging mercury drop electrode. The reaction mechanism was studied by direct current voltammetry and elimination voltammetry with linear scan. Optimum conditions for determination using differential pulse adsorption stripping voltammetry ofthis compound were found in Britton-Robinson buffer mixed with ethanol (4:1 v/v). The limits of detection were calculated as 8.9 x 10(-9) mol dm(-3) (with t (acc) = 20 s) for m-AgSAE and as 0.168 x 10(-6) mol dm(-3) (with t (acc) = 20 s) for p-AgSAE. The proposed method was successfully applied for determination of amitraz in real samples of river water. [GRAPHICS] .
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP208%2F12%2F1645" target="_blank" >GAP208/12/1645: Aspekty transportu rizikových kovů přes biologické membrány</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte für Chemie
ISSN
0026-9247
e-ISSN
—
Svazek periodika
147
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
9
Strana od-do
181-189
Kód UT WoS článku
000367521400024
EID výsledku v databázi Scopus
—