Voltammetric determination of sodium anthra-quinone-2-sulfonate (AQ) was investigated at a polished silver solid amalgam electrode (p-AgSAE) and at a mercury meniscus modified silver solid amalgam electrode (m-AgSAE) (inner diameter of both 0.5 mm). The reaction mechanisms of AQ at p-AgSAE and at m-AgSAE were studied by cyclic voltammetry, direct current voltammetry, and by elimination voltammetry with linear scan. Limits of detection obtained by differential pulse voltammetry were 1 9 10(-6) mol dm(-3) for p-AgSAE and 4 9 10(-7) mol dm(-3) for m-AgSAE. Both electrodes were successfully applied for differential pulse voltammetry of AQ in model samples of deionized water, river water, and human urine.
Název v anglickém jazyce
Voltammetric determination of sodium anthraquinone-2-sulfonate using silver solid amalgam electrodes
Popis výsledku anglicky
Voltammetric determination of sodium anthra-quinone-2-sulfonate (AQ) was investigated at a polished silver solid amalgam electrode (p-AgSAE) and at a mercury meniscus modified silver solid amalgam electrode (m-AgSAE) (inner diameter of both 0.5 mm). The reaction mechanisms of AQ at p-AgSAE and at m-AgSAE were studied by cyclic voltammetry, direct current voltammetry, and by elimination voltammetry with linear scan. Limits of detection obtained by differential pulse voltammetry were 1 9 10(-6) mol dm(-3) for p-AgSAE and 4 9 10(-7) mol dm(-3) for m-AgSAE. Both electrodes were successfully applied for differential pulse voltammetry of AQ in model samples of deionized water, river water, and human urine.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
<a href="/cs/project/GBP206%2F12%2FG151" target="_blank" >GBP206/12/G151: Centrum nových přístupů k bioanalýze a molekulární diagnostice</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Monatshefte fur Chemie
ISSN
0026-9247
e-ISSN
—
Svazek periodika
148
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
7
Strana od-do
577-583
Kód UT WoS článku
000396528600025
EID výsledku v databázi Scopus
2-s2.0-85011844858