HPLC-ED/UV with Solid Phase Extraction for the Determination of 5-Hydroxyindole-3-acetic Acid
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F18%3A10375980" target="_blank" >RIV/00216208:11310/18:10375980 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/18:00490024
Výsledek na webu
<a href="https://www.bestservis.eu/images/file/Sbornik_metody18_pdf/Sbornik_metody18.pdf" target="_blank" >https://www.bestservis.eu/images/file/Sbornik_metody18_pdf/Sbornik_metody18.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
HPLC-ED/UV with Solid Phase Extraction for the Determination of 5-Hydroxyindole-3-acetic Acid
Popis výsledku v původním jazyce
Tumour biomarker, 5-hydroxyindole-3-acetic acid, has been determined in human urine using HPLC with electrochemical (at a glassy carbon electrode in a "wall-jet" arrangement) and spectrophotometric detection (ED/UV) with solid phase extraction (SPE). Mobile phase was acetate-phosphate buffer at pH 2.5, gradient elution (increasing content of acetonitrile from 5 to 25% in 10 minutes) was used, flow rate of mobile phase was set up to 1 ml.minMINUS SIGN 1, detection potential to +1.1 V and detection wavelength of 279 nm. Injected volume was 20 μl. Dependence of the peak current on the analyte concentration was linear in the whole tested concentration range (from 10 to 150 μmol.l-1) and obtained limits of detection (LODs) for HPLC-ED were 0.85 μmol.l-1 (calculated from peak height) and 0.72 μmol.l-1 (calculated from peak area). For HPLC-UV, LODs were 3.30 μmol.l-1 (calculated from peak height) and 2.25 μmol.l-1 (calculated from peak area).
Název v anglickém jazyce
HPLC-ED/UV with Solid Phase Extraction for the Determination of 5-Hydroxyindole-3-acetic Acid
Popis výsledku anglicky
Tumour biomarker, 5-hydroxyindole-3-acetic acid, has been determined in human urine using HPLC with electrochemical (at a glassy carbon electrode in a "wall-jet" arrangement) and spectrophotometric detection (ED/UV) with solid phase extraction (SPE). Mobile phase was acetate-phosphate buffer at pH 2.5, gradient elution (increasing content of acetonitrile from 5 to 25% in 10 minutes) was used, flow rate of mobile phase was set up to 1 ml.minMINUS SIGN 1, detection potential to +1.1 V and detection wavelength of 279 nm. Injected volume was 20 μl. Dependence of the peak current on the analyte concentration was linear in the whole tested concentration range (from 10 to 150 μmol.l-1) and obtained limits of detection (LODs) for HPLC-ED were 0.85 μmol.l-1 (calculated from peak height) and 0.72 μmol.l-1 (calculated from peak area). For HPLC-UV, LODs were 3.30 μmol.l-1 (calculated from peak height) and 2.25 μmol.l-1 (calculated from peak area).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-03868S" target="_blank" >GA17-03868S: Nové metody elektrochemického sledování biologicky aktivních organických látek v environmentálních, biologických a potravinových matricích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXXVIII. Moderní Elektrochemické Metody: Sborník přednášek
ISBN
978-80-905221-6-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
147-150
Název nakladatele
Srsenová Lenka - Best servis Ústí nad Labem
Místo vydání
Ústí nad Labem
Místo konání akce
Jetrichovice, Česká republika
Datum konání akce
21. 5. 2018
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000464596500033