HPLC-ED/UV for determination of vanillylmandelic acid in human urine after solid phase extraction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F18%3A10409569" target="_blank" >RIV/00216208:11310/18:10409569 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/18:00498465
Výsledek na webu
<a href="https://web.natur.cuni.cz/analchem/isc-mac/" target="_blank" >https://web.natur.cuni.cz/analchem/isc-mac/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
HPLC-ED/UV for determination of vanillylmandelic acid in human urine after solid phase extraction
Popis výsledku v původním jazyce
HPLC with electrochemical and spectrophotometric detection (ED/UV) after solid phase extraction (SPE) was used for determination of vanillylmandelic acid in human urine. HPLC-ED was performed at a glassy carbon electrode in a "wall-jet" arrangement in acetate-phosphate buffer at pH = 2.5 and gradient elution (increasing content of acetonitrile from 5 to 25% in 10 minutes) was used. Optimized parameters were following: flow rate of mobile phase 1 mL min(-1), detection potential +1.1 V, detection wavelength 279 nm, injected volume 20 mu L. Dependence of the peak current on the analyte concentration was linear in the concentration range from 10 to 150 mu mol L-1, with obtained limits of detection 2.6 mu mol L-1 (calculated from peak height) and 1.9 mu mol L-1 (calculated from peak area) for HPLC-ED, and 11.0 mu mol L-1 (calculated from peak height) and 9.8 mu mol L-1 (calculated from peak area) for HPLC-UV.
Název v anglickém jazyce
HPLC-ED/UV for determination of vanillylmandelic acid in human urine after solid phase extraction
Popis výsledku anglicky
HPLC with electrochemical and spectrophotometric detection (ED/UV) after solid phase extraction (SPE) was used for determination of vanillylmandelic acid in human urine. HPLC-ED was performed at a glassy carbon electrode in a "wall-jet" arrangement in acetate-phosphate buffer at pH = 2.5 and gradient elution (increasing content of acetonitrile from 5 to 25% in 10 minutes) was used. Optimized parameters were following: flow rate of mobile phase 1 mL min(-1), detection potential +1.1 V, detection wavelength 279 nm, injected volume 20 mu L. Dependence of the peak current on the analyte concentration was linear in the concentration range from 10 to 150 mu mol L-1, with obtained limits of detection 2.6 mu mol L-1 (calculated from peak height) and 1.9 mu mol L-1 (calculated from peak area) for HPLC-ED, and 11.0 mu mol L-1 (calculated from peak height) and 9.8 mu mol L-1 (calculated from peak area) for HPLC-UV.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-03868S" target="_blank" >GA17-03868S: Nové metody elektrochemického sledování biologicky aktivních organických látek v environmentálních, biologických a potravinových matricích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 14th International Students Conference “Modern Analytical Chemistry“
ISBN
978-80-7444-059-5
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
82-86
Název nakladatele
Univerzita Karlova, Přírodovědecká fakulta
Místo vydání
Praha 2
Místo konání akce
Charles University, Praha
Datum konání akce
20. 9. 2018
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000495572500014