Determination of Aminoglutethimide Using HPLC-ED on CPE
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F11%3A10105116" target="_blank" >RIV/00216208:11310/11:10105116 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.bestservis.eu/Rakce/lang" target="_blank" >http://www.bestservis.eu/Rakce/lang</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Aminoglutethimide Using HPLC-ED on CPE
Popis výsledku v původním jazyce
This work deals with the determination of aminoglutethimide (AGT) using high performance liquid chromatography with UV spectrophotometric detection (HPLC-UV) and amperometric detection (HPLC-ED) on carbon paste electrode (CPE). AGT was used as anticancerdrug, especially for the treatment of breast cancer in postmenopausal women or for the treatment of prostate cancer. The concentration dependences of AGT were measured by HPLC-UV with detection wavelength 242 nm, by HPLC-ED with a working potencial of +1.3 V in mobile phase consisting of 1.10-2 mol l-1 phosphate buffer (pH 4) and methanol 50:50 (v/v). The following limits of detection were achieved : 3.6.10-7 mol l-1 AGT for UV spectrophotometric detection, 2.5.10-7 mol l-1 AGT for amperometric detection. AGT was also determined in model samples of urine. It was not possible to detect AGT with HPLC-UV, because of the interferences of other compounds. With HPLC-ED the detection limit 5.2.10-7 mol l-1 AGT was achieved.
Název v anglickém jazyce
Determination of Aminoglutethimide Using HPLC-ED on CPE
Popis výsledku anglicky
This work deals with the determination of aminoglutethimide (AGT) using high performance liquid chromatography with UV spectrophotometric detection (HPLC-UV) and amperometric detection (HPLC-ED) on carbon paste electrode (CPE). AGT was used as anticancerdrug, especially for the treatment of breast cancer in postmenopausal women or for the treatment of prostate cancer. The concentration dependences of AGT were measured by HPLC-UV with detection wavelength 242 nm, by HPLC-ED with a working potencial of +1.3 V in mobile phase consisting of 1.10-2 mol l-1 phosphate buffer (pH 4) and methanol 50:50 (v/v). The following limits of detection were achieved : 3.6.10-7 mol l-1 AGT for UV spectrophotometric detection, 2.5.10-7 mol l-1 AGT for amperometric detection. AGT was also determined in model samples of urine. It was not possible to detect AGT with HPLC-UV, because of the interferences of other compounds. With HPLC-ED the detection limit 5.2.10-7 mol l-1 AGT was achieved.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Moderní elektrochemické metody: sborník přednášek XXXI. mezinárodní odborné konference: Jetřichovice 23. ? 27. května 2011
ISBN
978-80-254-9634-3
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
181-184
Název nakladatele
BEST servis Ústí nad Labem
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice
Datum konání akce
23. 5. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—