Indirect Detection of DNA Damage at Silver Solid Amalgam Electrodes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F19%3A10409211" target="_blank" >RIV/00216208:11310/19:10409211 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.bestservis.eu/images/file/sb_mem_19/Sbornik_metody19.pdf" target="_blank" >https://www.bestservis.eu/images/file/sb_mem_19/Sbornik_metody19.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Indirect Detection of DNA Damage at Silver Solid Amalgam Electrodes
Popis výsledku v původním jazyce
Cyclic voltammetry and differential pulse voltammetry together with electrochemical impedance spectroscopy were used for an electrochemical study of methylene blue at bare and DNA-modified silver solid amalgam electrode. Methylene blue gave a specific cathodic signal, and this signal is significantly higher at DNA-modified than at unmodified amalgam electrode, which is in correspondence with the changes of charge resistance transfer values obtained from Nyquist plots. The integrity of dsDNA layer was tested indirectly using differential pulse voltammetry of intercalated methylene blue after the previous UV irradiation of the biosensor surface at two different wavelengths. Individual electrochemical signals depend on the time of biosensor incubation in methylene blue, time of the exposure to UV radiation, and selected wavelengths.
Název v anglickém jazyce
Indirect Detection of DNA Damage at Silver Solid Amalgam Electrodes
Popis výsledku anglicky
Cyclic voltammetry and differential pulse voltammetry together with electrochemical impedance spectroscopy were used for an electrochemical study of methylene blue at bare and DNA-modified silver solid amalgam electrode. Methylene blue gave a specific cathodic signal, and this signal is significantly higher at DNA-modified than at unmodified amalgam electrode, which is in correspondence with the changes of charge resistance transfer values obtained from Nyquist plots. The integrity of dsDNA layer was tested indirectly using differential pulse voltammetry of intercalated methylene blue after the previous UV irradiation of the biosensor surface at two different wavelengths. Individual electrochemical signals depend on the time of biosensor incubation in methylene blue, time of the exposure to UV radiation, and selected wavelengths.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXXIX. Moderní Elektrochemické Metody: Sborník přednášek
ISBN
978-80-905221-7-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
193-196
Název nakladatele
Srsenová Lenka - Best servis Ústí nad Labem
Místo vydání
Ústí nad Labem
Místo konání akce
Jetrichovice, Česká republika
Datum konání akce
20. 5. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000583689900045